MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000521923

Медицинская библиотека · Blood purification · 2022

Extracorporeal Removal of Myoglobin in Patients with Rhabdomyolysis and Acute Kidney Injury: Comparison of High and Medium Cut-Off Membrane and an Adsorber Cartridge.

Jerman Alexander, Andonova Milena, Persic Vanja, Gubensek Jakob

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The role of extracorporeal myoglobin removal in the treatment of rhabdomyolysis-associated severe acute kidney injury (AKI) is not yet fully established. High cut-off (HCO) and medium cut-off (MCO) dialysis membrane and cytokine adsorber (CytoSorb®) have been used to this purpose in clinical practice. The data on comparative effectiveness of those methods are scarce.

METHODS

In this single-center retrospective study, we included patients with AKI and concomitant rhabdomyolysis (myoglobin >20,000 μg/L), who underwent at least one extracorporeal myoglobin removal procedure. The main outcome parameter was myoglobin reduction ratio, whereas albumin was assessed as a safety parameter.

RESULTS

We analyzed data for 15 patients, who underwent 28 procedures (13 HCO, 9 MCO, and 6 adsorber). Pre-treatment serum myoglobin levels were similar between the groups and myoglobin reduction was significant in HCO (p = 0.03) and MCO groups (p < 0.01) and borderline significant in adsorber group (p = 0.06). Reduction ratios were comparable between the groups (median 0.64 (inter-quartile range IQR 0.13-0.72), 0.54 (IQR 0.51-0.61) and 0.50 (IQR 0.37-0.62), respectively, p = 0.83). Both pre- and post-procedure serum albumin levels were significantly lower in the MCO group. However, with routine albumin substitution in the HCO group only, serum albumin remained stable during the procedures in all subgroups.

CONCLUSIONS

Novel MCO membrane might represent the optimal mode of treatment of severe rhabdomyolysis-associated AKI, as it allows for efficient removal of myoglobin, avoids albumin supplementation and is associated with lower costs. For patients requiring cytokine removal, the adsorption capsule can simultaneously reduce cytokine and myoglobin levels.

Для цитирования: Jerman Alexander, Andonova Milena, Persic Vanja, Gubensek Jakob. Extracorporeal Removal of Myoglobin in Patients with Rhabdomyolysis and Acute Kidney Injury: Comparison of High and Medium Cut-Off Membrane and an Adsorber Cartridge.. Blood purification. 2022. DOI: 10.1159/000521923.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.