MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pmrj.12393

Медицинская библиотека · PM & R : the journal of injury, function, and rehabilitation · 2020

Validating Wearable Sensors Using Self-Reported Instability among Patients with Knee Osteoarthritis.

Na Annalisa, Buchanan Thomas S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Self-perceived instability among patients with knee osteoarthritis (OA) is defined as giving way, buckling, or shifting of the knee during activities, especially walking. Although instability is a leading cause of mobility decline with knee OA, methods for quantifying the symptom, determining the mechanisms, and establishing effective interventions remain unclear. Recently, data outputs (ie, linear acceleration and its time-derivative, jerk) from wearable sensors are showing strong associations with self-perceived instability among patients with other knee pathologies and may offer insight into OA-related instability.

OBJECTIVE

To examine discriminant and convergent validity of using data outputs from wearable sensors to quantify self-reported instability among patients with knee OA.

DESIGN

Secondary analysis of a cross-sectional study.

SETTING

Primary recruitment from an institutional outpatient physical therapy clinic and collection completed in an institutional research laboratory.

PATIENTS: Thirty-nine total participants. The OA group included 26 participants with radiographic evidence of moderate to severe knee OA in the medial compartment; knee pain >3 out of 10, and a walking speed of ≥1.0 m/s. The control group included 13 participants with no history of knee OA. Participants with current or history of low back, hip, or foot/ankle injury; knee replacement; skeletal realignment surgery; or comorbidities that limit walking, pregnancy, and inability to walk without an assistive device were excluded.

INTERVENTIONS: N/A MAIN OUTCOME MEASURES: Data output from wearable sensors at the tibia.

RESULTS

Midstance acceleration (P = .01) and jerk (P = .04) were significantly greater for those with than without knee OA. Acceleration was significantly associated with self-reported instability (Spearman's rho = -0.63, P < .01).

CONCLUSIONS

Data from wearable sensors are a valid measurement for exploring the mechanisms and risks of instability among patients with knee OA.

Для цитирования: Na Annalisa, Buchanan Thomas S. Validating Wearable Sensors Using Self-Reported Instability among Patients with Knee Osteoarthritis.. PM & R : the journal of injury, function, and rehabilitation. 2020. DOI: 10.1002/pmrj.12393.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.