INTRODUCTION

Automated, objective assessment of rehabilitation movement quality from three-dimensional skeleton recordings can support scalable and low-cost physiotherapy monitoring, but reported performance is often affected by subject leakage, inconsistent class-imbalance handling and non-comparable evaluation protocols.

METHODS

This study establishes a leakage-controlled, subject-independent benchmark on the publicly available IntelliRehabDS corpus. After removing 12 ambiguous-label files and 2 sequences shorter than 16 frames, 2,575 sequences from 29 adult and adolescent participants were retained, comprising 2,047 correct and 528 incorrect executions across nine rehabilitation gestures. Sequences were root-centred, torso-scaled, smoothed with a Savitzky-Golay filter, resampled to 64 frames and represented through kinematic features or skeleton tensors. Five classical feature-based learners and the topology-aware ST-SkelNet sequence model were evaluated through nested subject-wise cross-validation. Scaling and SMOTE were fitted only within the relevant training partitions for the classical models, whereas ST-SkelNet used class-weighted binary cross-entropy.

RESULTS

Performance was reported using fold-averaged metrics, pooled out-of-fold confusion matrices and ROC-AUC analysis. No single model dominated: the multilayer perceptron achieved the highest accuracy (0.869), the random forest the highest ROC-AUC (0.861), and the support vector machine the highest incorrect-class recall (0.629). ST-SkelNet achieved 0.846 accuracy, 0.855 ROC-AUC and 0.612 incorrect-class recall, but did not consistently exceed the strongest classical baselines. Head-motion and bilateral-asymmetry features showed descriptive separation between correct and incorrect executions in this adult/adolescent cohort.

DISCUSSION: The contribution is a reproducible methodological benchmark rather than a clinical system or a state-of-the-art architecture. IntelliRehabDS is treated here as a surrogate adult/adolescent dataset for methodological validation and benchmarking, not as infant data. Transfer to paediatric populations, including congenital muscular torticollis, requires independently collected age-specific data and prospective clinical validation.

Для цитирования: Zhu Zhen, Xiang Yuqiong, Tian Xianzhu. Skeleton-based rehabilitation movement quality classification: a leakage-controlled benchmark on IntelliRehabDS.. Frontiers in medicine. 2026. DOI: 10.3389/fmed.2026.1878438.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.