MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1197/jamia.m1330

Медицинская библиотека · Journal of the American Medical Informatics Association : JAMIA · 2003

Creating a text classifier to detect radiology reports describing mediastinal findings associated with inhalational anthrax and other disorders.

Chapman Wendy Webber, Cooper Gregory F, Hanbury Paul, Chapman Brian E, Harrison Lee H, Wagner Michael M

Оценочное исследованиеСтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to create a classifier for automatic detection of chest radiograph reports consistent with the mediastinal findings of inhalational anthrax.

DESIGN

The authors used the Identify Patient Sets (IPS) system to create a key word classifier for detecting reports describing mediastinal findings consistent with anthrax and compared their performances on a test set of 79,032 chest radiograph reports.

MEASUREMENTS: Area under the ROC curve was the main outcome measure of the IPS classifier. Sensitivity and specificity of an initial IPS model were calculated based on an existing key word search and were compared against a Boolean version of the IPS classifier.

RESULTS

The IPS classifier received an area under the ROC curve of 0.677 (90% CI = 0.628 to 0.772) with a specificity of 0.99 and maximum sensitivity of 0.35. The initial IPS model attained a specificity of 1.0 and a sensitivity of 0.04.

CONCLUSION

The IPS system is a useful tool for helping domain experts create a statistical key word classifier for textual reports that is a potentially useful component in surveillance of radiographic findings suspicious for anthrax.

Для цитирования: Chapman Wendy Webber, Cooper Gregory F, Hanbury Paul, Chapman Brian E, Harrison Lee H, Wagner Michael M. Creating a text classifier to detect radiology reports describing mediastinal findings associated with inhalational anthrax and other disorders.. Journal of the American Medical Informatics Association : JAMIA. 2003. DOI: 10.1197/jamia.m1330.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.