MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bpo.0000000000000531

Медицинская библиотека · Journal of pediatric orthopedics · 2016

Temperature Change When Drilling Near the Distal Femoral Physis in a Skeletally Immature Ovine Model.

Tenfelde Allison M, Esquivel Amanda O, Cracchiolo Allison M, Lemos Stephen E

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The possibility of physeal injury during anterior cruciate ligament reconstruction in the pediatric population is a concern. The purpose of this study was to determine whether drilling at or near the physis could cause a temperature increase that could trigger chondrolysis.

METHODS

Skeletally immature cadaveric lamb distal femurs were used for this study and randomly placed in 1 of 6 groups (n=10 in each group). We examined the 8 and 10 mm Flipcutter at a distance of 0.5 mm from the physis and an 8 and 10 mm acorn-tipped reamer at a distance of 0.5 and 3.0 mm from the physis. During drilling, temperature change at the distal femoral physis was continuously measured until the temperature decreased to the original value.

RESULTS

An interreamer comparison yielded a significant difference when drilling 0.5 mm from the physis (P=0.001). Pair-wise Mann-Whitney post hoc tests were performed to further evaluate the differences among the groups. The 8 mm FlipCutter had a significantly higher maximum temperature (39.8±1.4°C) compared with the 10 mm FlipCutter (38.0±0.6°C, P=0.001), 8 mm acorn-tipped reamer (38.1±0.9°C, P=0.007), and 10 mm acorn-tipped reamer (37.5±0.3°C, P<0.001).

CONCLUSIONS

The risk of thermal-induced injury to the physis is low with an all epiphyseal drilling technique, when a traditional acorn-tipped reamer over a guidepin is utilized, even if the drilling occurs very close to the physis. In addition, the risk of drilling with a FlipCutter is low, but may be greater than a traditional reamer.

CLINICAL RELEVANCE: Thermal-induced necrosis is a realistic concern, due to the characteristics of the distal femoral physis, and the propensity for this physis to respond poorly to injury. Our study supports that drilling near the physis can be done safely, although smaller reamers and nontraditional designs may generate higher heat.

LEVEL OF EVIDENCE: Level I-basic science.

Для цитирования: Tenfelde Allison M, Esquivel Amanda O, Cracchiolo Allison M, Lemos Stephen E. Temperature Change When Drilling Near the Distal Femoral Physis in a Skeletally Immature Ovine Model.. Journal of pediatric orthopedics. 2016. DOI: 10.1097/bpo.0000000000000531.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.