Influence of kinematics of the lumbopelvic complex in hip arthroplasty dislocation: from assessment to recommendations.

Kouyoumdjian Pascal, Mansour Jad, Marouby Stanislas, Canovas Francois, Dagneaux Louis, Coulomb Remy

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

In total hip arthroplasty (THA), misplacement of the implant can provide instability. Adequate orientation of the acetabular cup is a challenge due to variations in inter-individual anatomy and kinematics of the pelvis in everyday life. The aim of this study was to characterize the kinematic factors influencing the risk of dislocation in order to give recommendations for optimal placement of the cup. We hypothesized that the lack of pelvic adaptation would influence the risk of prosthetic instability and motivate adapted.

MATERIALS AND

METHODS

Eighty patients with primary unilateral THA were included in a matched case-control study. Seventy-four patients were divided into two groups: group 1 (G1) consisting of patients with postoperative THA dislocation (37 patients) and group 2 (G2), without episodes of dislocation within two years postoperatively (37 patients). In both groups, spino-pelvic parameters and cup orientation were measured in standing and sitting positions with EOS® X-ray imaging and compared to each other between 12 and 24 months post-operatively.

RESULTS

No significant difference between the two groups was found for static parameters. In a sitting position, a lack of pelvic retroversion with a significant lower variation in sacral slope was observed in group 1 (8.0° ± 9.3 for G1 versus 14.7° ± 6.2 for G2, p < 0.01). Twenty-two (59%) patients with THA instability had sacral slope variations of less than 10° versus eight (21% of patients) with stable THA (p < 0.01). Cup orientation in the Lewinnek safe zone was not significantly different (59% vs 67%, p = 0.62), and the spino-pelvic parameters and cup orientation measured did not change between the standing and sitting positions. However, only 14 (37%) cups in G1 were in the functional safe zone versus 24 (67%) in G2 (p = 0.03).

CONCLUSION

Static parameters of the sagittal spinopelvic balance have a low predictive value for prosthetic instability. Dynamic analysis is essential. Kinematic parameters must be taken into account in determining the ideal position of the cup or stem. Stiffness with locked standing or sitting pelvis must be integrated in order to determine a personalized safe zone.

LEVEL OF EVIDENCE: Level III (matched case-control study).

Для цитирования: Kouyoumdjian Pascal, Mansour Jad, Marouby Stanislas, Canovas Francois, Dagneaux Louis, Coulomb Remy. Influence of kinematics of the lumbopelvic complex in hip arthroplasty dislocation: from assessment to recommendations.. Archives of orthopaedic and trauma surgery. 2023. DOI: 10.1007/s00402-022-04722-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.