MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0019-5413.108912

Медицинская библиотека · Indian journal of orthopaedics · 2013

Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients.

Satish Bhava Rj, Ranganadham Atmakuri V, Ramalingam Karruppasamy, Tripathy Sujit Kumar

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The treatment options for displaced femoral neck fracture in elderly are screw fixation, hemiarthroplasty and total hip arthroplasty based primarily on age of the patient. The issues in screw fixation are ideal patient selection, optimal number of screws, optimal screw configuration and positioning inside the head and neck of femur. The problems of screw fixation may be loss of fixation, joint penetration, avascular necrosis of femoral head, nonunion, prolonged rehabilitation period and the need for second surgery in failed cases. We hereby present results of a modified screw fixation technique in femoral neck fractures in patients ≥50 years of age.

MATERIALS AND

METHODS

Patients ≥50 years of age (range 50-73 years) who sustained displaced femoral neck fracture and fulfilled the inclusion criteria were enrolled in this prospective study. They were treated with closed reduction under image intensifier control and cannulated cancellous screw fixation. Accurate anatomical reduction was not aimed and a cross sectional contact area of >75% without varus was accepted as good reduction. Four screws were positioned in four quadrants of femoral head and neck, as parallel and as peripheral as possible. Radiological and functional results were evaluated periodically. Sixty four patients who could complete a minimum followup of two years were analyzed.

RESULTS

Radiologically, all fractures healed after mean duration of 10 weeks (range 8-12 weeks). There was no avascular necrosis. Nonanatomical healing was observed in 45 cases (70%). All patients except one had excellent functional outcome and could do cross-legged sitting and squatting. Chondrolysis with progressive head resorption was seen in one case, which was converted to total hip arthroplasty.

CONCLUSION

Closed reduction and cannulated cancellous screw fixation gives satisfactory functional results in large group of elderly patients. The four quadrant parallel peripheral (FQPP) screw fixation technique gives good stability, allows controlled collapse, avoids fixation failure and achieves predictable bone healing in displaced femoral neck fracture in patients ≥50 years of age.

Для цитирования: Satish Bhava Rj, Ranganadham Atmakuri V, Ramalingam Karruppasamy, Tripathy Sujit Kumar. Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients.. Indian journal of orthopaedics. 2013. DOI: 10.4103/0019-5413.108912.
Подготовка и перевод публикации