Reduced-distortion diffusion weighted imaging for head and neck radiotherapy.

Aliotta Eric, Paudyal Ramesh, Dresner Alex, Shukla-Dave Amita, Lee Nancy, Cerviño Laura, Otazo Ricardo, Yu Victoria Y

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Quantitative Diffusion Weighted Imaging (DWI) has potential value in guiding head and neck (HN) cancer radiotherapy. However, clinical translation has been hindered by severe distortions in standard single-shot Echo-Planar-Imaging (ssEPI) and prolonged scan time and low SNR in Turbo-Spin-Echo (ssTSE) sequences. In this study, we evaluate "multi-shot" (ms) msEPI and msTSE acquisitions in the context of HN radiotherapy.

MATERIALS AND

METHODS

ssEPI, ssTSE, msEPI with 2 and 3 shots (2sEPI, 3sEPI), and msTSE DWI were acquired in a phantom, healthy volunteers (N=10), and patients with HN cancer (N=5) on a 3-Tesla wide-bore MRI in radiotherapy simulation RF coil setup, with matched spatial resolution (2x2x5mm) and b = 0, 200, 800 s/mm2.Geometric distortions measured with deformable vector field (DVF) and contour analysis, apparent diffusion coefficient (ADC) values, and signal-to-noise-ratio efficiency (SNReff) were quantified for all scans.

RESULTS

All techniques significantly (P<1x10-3) reduced distortions compared with ssEPI (DVFmean = 3.1 ± 1.3 mm). Distortions were marginally lower for msTSE (DVFmean = 1.5 ± 0.6 mm) than ssTSE (1.8 ± 0.9 mm), but were slightly higher with 2sEPI and 3sEPI (2.6 ± 1.0 mm, 2.2 ± 1.0 mm). SNReff reduced with decreasing distortion with ssEPI=21.9 ± 7.9, 2sEPI=15.1 ± 5.0, 3sEPI=12.1 ± 4.5, ssTSE=6.0 ± 1.6, and msTSE=5.7 ± 1.9 for b = 0 images. Phantom ADC values were consistent across all protocols (errors ≤ 0.03x10-3mm2/s), but in vivo ADC values were ∼ 4 % lower with msEPI and ∼ 12 % lower with ssTSE/msTSE compared with ssEPI.

CONCLUSIONS

msEPI and TSE acquisitions exhibited improved geometric distortion at the cost of SNReff and scan time. While msTSE exhibited the least distortion, 3sEPI may offer an appealing middle-ground with improved geometric fidelity but superior efficiency and in vivo ADC quantification.

Для цитирования: Aliotta Eric, Paudyal Ramesh, Dresner Alex, Shukla-Dave Amita, Lee Nancy, Cerviño Laura, Otazo Ricardo, Yu Victoria Y. Reduced-distortion diffusion weighted imaging for head and neck radiotherapy.. Physics and imaging in radiation oncology. 2024. DOI: 10.1016/j.phro.2024.100653.