MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02841851231169725

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2023

Relationship between patellofemoral joint morphology and chondromalacia patella.

Öztürk Cansu, Güngör Özlem

СтатьяПеревод в очереди

Аннотация

BACKGROUND

For the normal functioning of the patellofemoral joint (PF), the relationship between the patella and the trochlear groove must be compatible.

PURPOSE: To investigate the relationship between patellofemoral joint morphology (PFM) and patellar chondromalacia.

MATERIAL AND

METHODS

Overall, 136 knees of patients aged 20-55 years examined between March 2020 and March 2021 were included in this study. In all patients, trochlear sulcus angle, trochlear sulcus depth, trochlear facet asymmetry, patella alta (Insall-Salvati [IS] index), and patellar facet asymmetry were measured. Of these cases, 66 knees with an abnormality detected in any of the measurements for PFM were included in the case group. Moreover, 70 knees with demonstrating normal PFM measurements were included in the control group.

RESULTS

The incidence and grade of chondromalacia was higher in the case group than in the control group (P < 0.001). Between the patients with and without chondromalacia trochlear sulcus angle (mean = 138.25° ± 10.02° vs. 132.58° ± 7.24°; P = 0.001), IS index (mean = 1.25 ± 0.21 vs. 1.16 ± 0.15; P = 0.014), patellar facet asymmetry (mean = 0.77 ± 0.09 vs. 0.73 ± 0.12; P = 0.039), trochlear sulcus depth (mean = 5.39 ± 1.42 mm vs. 6.27 ± 1.04 mm; P < 0.001), and trochlear facet asymmetry (mean = 0.67 ± 0.11 vs. 0.71 ± 0.09; P = 0.023) measurements, there was a significant difference.

CONCLUSION

The presence of at least one of the measures indicating pathology in PFM is associated with the presence and severity of chondromalacia.

Для цитирования: Öztürk Cansu, Güngör Özlem. Relationship between patellofemoral joint morphology and chondromalacia patella.. Acta radiologica (Stockholm, Sweden : 1987). 2023. DOI: 10.1177/02841851231169725.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.