A syringe adapter for reduced muscular strain and fatigue.

Ulbrich Joseph, Swader Robert, Petry George, Cox Benjamin L, Greene Runyu L, Eliceiri Kevin W, Radwin Robert G

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

Workers in hospitals, clinics, and contract research organizations who repetitively use syringes have an increased risk for musculoskeletal disorders. This study developed and tested a novel syringe adapter designed to reduce muscle strain associated with repetitive fluid draws. Three syringe plunger extension methods (ring-finger, middle-finger, and syringe adapter) were studied across twenty participants. Electromyogram signals for the flexor digitorum superficialis and extensor digitorum muscles were recorded. The syringe adapter required 31% of the 90th percentile flexor muscle activity as compared to the ring-finger syringe extension method, and 45% the 90th percentile flexor muscle activity as compared to the middle-finger method (p < 0.001). The greatest differences were observed when the syringe was near full extension. Although the syringe adapter took more time than the other syringe extension methods (1.5 times greater), it greatly helped reduce physical stress associated with repetitive, awkward syringe procedures.

Для цитирования: Ulbrich Joseph, Swader Robert, Petry George, Cox Benjamin L, Greene Runyu L, Eliceiri Kevin W, Radwin Robert G. A syringe adapter for reduced muscular strain and fatigue.. Applied ergonomics. 2020. DOI: 10.1016/j.apergo.2020.103061.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.