Hernia : the journal of hernias and abdominal wall surgery · 2024

Reliability and validity of surface EMG assessments combined with isometric muscle strength testing in patients with abdominal rectus diastasis and asymptomatic controls.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Swedenhammar E, Wahlström O, Brandt J D, Strigård K, Häger C, Stark B, Nyberg A

Аннотация

PURPOSE: Patients with abdominal rectus diastasis (ARD) may have muscular functional impairments, but clinics lack appropriate objective assessment tools. The aim was to establish the relative and absolute reliability, and convergent validity, of muscular activity using Surface Electromyography (SEMG) during isometric abdominal muscle strength testing in patients with ARD and controls without ARD.

METHODS: Twenty-six patients with ARD were matched for age, sex and BMI with controls without ARD. Participants were tested twice during isometric muscular contractions using SEMG located on six abdominal sites. Mean amplitude, fatigue, and recruitment order were analyzed. Relative reliability was evaluated with Intraclass Correlation Coefficients (ICC), while absolute reliability was estimated by calculating the Standard Error of Measurement and Minimal Detectable Change. Convergent validity was addressed in relation to participant characteristics, functional ability, and symptoms.

RESULTS: Mean SEMG amplitude for all abdominal wall muscle contractions showed moderate to excellent relative test-retest reliability, with ICC values ranging from 0.46 to 0.97. In contrast, fatigue and recruitment order displayed poor to moderate relative reliability in both groups. Absolute reliability measures were generally high. A moderate to high convergent validity (ARD: rho-value 0.41-0.70; Controls: rho-value 0.41-0.75) was observed for mean amplitude in relation to a functional sit-to-stand test, abdominal circumference, BMI, back pain, and quality-of-life.

CONCLUSIONS: The results of applying SEMG during isometric abdominal muscle support practicing the method in clinics, although additional development is needed with further standardization and more functional testing. Furthermore, the method demonstrates construct validity in patients with ARD and in age- and sex-matched controls.