MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40634-023-00670-4

Медицинская библиотека · Journal of experimental orthopaedics · 2023

Unrestricted kinematic alignment corrects fixed flexion contracture in robotically aligned total knees without raising the joint line in extension.

Sappey-Marinier Elliot, Bini Stefano

СтатьяПеревод в очереди

Аннотация

PURPOSE: Mechanically Aligned Total Knee Arthroplasty (MA TKA) typically addresses fixed flexion contractures (FFC) by raising the joint line during extension. However, in unrestricted Kinematically Aligned TKA (KA TKA) utilizing a caliper-based resection technique, the joint line is not raised. This study aims to determine the efficacy of KA TKA in restoring full extension in patients with FFC without increasing distal femoral resection, considering tibial bone resection and sagittal component positioning.

METHODS

A retrospective study was conducted by a single surgeon, involving patients who underwent primary robotically assisted cruciate retaining unrestricted KA TKA between June 1, 2021, and December 1, 2022. Complete intraoperative resection and alignment data were recorded, including the thickness of distal femoral and proximal tibial bone cuts. Patients with a preoperative FFC ≥ 5° (study group) were compared to those with FFC < 5° (control group). The impact of variations in tibial resection and sagittal component positioning was assessed by comparing the heights of medial and lateral resections, sagittal femoral component flexion, and tibial slope. Group comparisons were analyzed using the Wilcoxon Signed Rank Test, with a significance level set at p < 0.05.

RESULTS

A total of 48 KA TKA procedures met the inclusion criteria, with 24 performed on women. The mean preoperative FFC in the study group was 11.2° (range: 5-25°), while the control group exhibited 1° (range: 0-4°) (p < 0.001). There were no statistically significant differences observed between the study and control groups in terms of distal femoral resections, both medially (p = 0.14) and laterally (p = 0.23), as well as tibial resection heights, both medially (p = 0.66) and laterally (p = 0.74). The alignment of the femoral component flexion and tibial slope was comparable between the two groups (p = 0.31 and p = 0.54, respectively). All patients achieved within 5 degrees of full extension at closure.

CONCLUSION

Robotic arm-assisted unrestricted KA TKA effectively restores full extension without raising the joint line during extension for patients with a preoperative fixed flexion contracture.

LEVEL OF EVIDENCE: III.

Для цитирования: Sappey-Marinier Elliot, Bini Stefano. Unrestricted kinematic alignment corrects fixed flexion contracture in robotically aligned total knees without raising the joint line in extension.. Journal of experimental orthopaedics. 2023. DOI: 10.1186/s40634-023-00670-4.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.