Long-term results of a vitamin E-blended polyethylene liner in total hip arthroplasty: a minimum ten year computer aided design based evaluation of wear and component positioning.

Demir Eren, Rasuli Mahfuz, Nienhaus Michael, Schippers Philipp, Naisan Martin, Noufal Yazan, Drees Philipp, Afghanyar Yama

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Aseptic loosening remains a leading cause of revision in total hip arthroplasty (THA), with polyethylene wear representing a key contributing factor. Vitamin E-blended highly cross-linked polyethylene (VEPE) has been introduced to improve oxidative stability and long-term wear performance; however, long-term clinical data remain limited.

METHODS

This retrospective study evaluates long-term polyethylene wear and component positioning in a cohort of patients who underwent primary THA using a vitamin E-blended polyethylene monoblock acetabular component (RM Pressfit vitamys®). Patients were followed for a minimum of ten years. Radiographic assessment was performed using a fully automated, observer-independent CAD-based software (RayMatch®), enabling measurement of cup inclination, anteversion, and polyethylene wear through 2D-3D registration of implant CAD models.

RESULTS

A total of 57 hips with complete radiographic follow-up were analyzed. Mean polyethylene wear rates were 26.9 µm/year at five years and 18.2 µm/year at ten years, remaining well below commonly reported thresholds associated with osteolysis. Cup inclination remained stable over time, whereas a gradual increase in measured anteversion was observed during follow-up.

CONCLUSION

At a minimum ten year follow-up, the investigated vitamin E-blended polyethylene monoblock cup demonstrated favorable long-term wear characteristics and stable component positioning. Further comparative studies are warranted to compare its long-term performance with other acetabular cup and liner designs.

Для цитирования: Demir Eren, Rasuli Mahfuz, Nienhaus Michael, Schippers Philipp, Naisan Martin, Noufal Yazan, Drees Philipp, Afghanyar Yama. Long-term results of a vitamin E-blended polyethylene liner in total hip arthroplasty: a minimum ten year computer aided design based evaluation of wear and component positioning.. International orthopaedics. 2026. DOI: 10.1007/s00264-026-06997-8.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.