MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/gox.0000000000006976

Медицинская библиотека · Plastic and reconstructive surgery. Global open · 2025

Trigger Finger Release: A Technique for Ensuring Safe and Adequate Release.

Tarapore Rae, Wieland Mark D, Katz Ryan

СтатьяПеревод в очереди

Аннотация

Although trigger finger release is a safe and effective procedure, complications occur due to improper technique. Incomplete release of the A1 pulley risks relapse of triggering, whereas release of the A2 pulley places patients at risk for bowstringing. Complications are often the result of poor exposure, misplaced incisions, and difficulty visualizing where the A1 pulley ends and the A2 pulley begins. The transition between A1 and A2 may be distinct in some patients and obscure in others. With the A1 pulley being the most common site of triggering, the purpose of this article was to illustrate a safe, effective, and reproducible technique for A1 pulley release. The following technique relies upon the anatomical principle that the A1 pulley is contiguous with the volar plate. The technique begins with the surgeon sharply incising the A1 pulley proximally. To assess adequate release, surgeons can place the cut portion of the pulley on lateral tension while shifting the visible flexor tendons either radially or ulnarly with the goal of visualizing the "underside" (eg, synovial side) of the A1 pulley where it is contiguous with the volar plate. Because the demarcation of the borders of the A1 pulley is clearer and more distinct on the synovial side, and because the A1 pulley is contiguous with the volar plate, visualization of the adequacy of release is easily achieved. If release of the A1 pulley is inadequate, the entire volar plate will not be easily visualized. This technique ensures safe, effective, and reproducible outcomes.

Для цитирования: Tarapore Rae, Wieland Mark D, Katz Ryan. Trigger Finger Release: A Technique for Ensuring Safe and Adequate Release.. Plastic and reconstructive surgery. Global open. 2025. DOI: 10.1097/gox.0000000000006976.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.