MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00259-020-04694-1

Медицинская библиотека · European journal of nuclear medicine and molecular imaging · 2020

Direct prospective comparison of 18F-FDG PET and arterial spin labelling MR using simultaneous PET/MR in patients referred for diagnosis of dementia.

Ceccarini Jenny, Bourgeois Sophie, Van Weehaeghe Donatienne, Goffin Karolien, Vandenberghe Rik, Vandenbulcke Mathieu, Sunaert Stefan, Van Laere Koen

СтатьяПеревод в очереди

Аннотация

PURPOSE: 18F-FDG PET is routinely used as an imaging marker in the early and differential diagnosis of dementing disorders and has incremental value over the clinical neurological and neuropsychological evaluation. Perfusion MR imaging by means of arterial spin labelling (ASL) is an alternative modality to indirectly measure neuronal functioning and could be used as complement measurement in a single MR session in the workup of dementia. Using simultaneous PET-MR, we performed a direct head-to-head comparison between enhanced multiplane tagging ASL (eASL) and 18F-FDG PET in a true clinical context of subjects referred for suspicion of neurodegenerative dementia.

METHODS

Twenty-seven patients underwent a 20-min 18F-FDG PET/MR and simultaneously acquired eASL on a GE Signa PET/MR. Data were compared with 30 screened age- and gender-matched healthy controls. Both integral eASL and 18F-FDG datasets were analysed visually by two readers unaware of the final clinical diagnosis, either in normal/abnormal classes, or full differential diagnosis (normal, Alzheimer type dementia [AD], dementia with Lewy Bodies [LBD], frontotemporal dementia [FTD] or other). Reader confidence was assessed with a rating scale (range 1-4). Data were also analysed semiquantitatively by VOI and voxel-based analyses.

RESULTS

The ground truth diagnosis for the patient group resulted in 14 patients with a neurodegenerative cognitive disorder (AD, FTD, LBD) and 13 patients with no arguments for an underlying neurodegenerative cause. Visual analysis resulted in equal specificity (0.70) for differentiating normal and abnormal cases between the two modalities, but in a higher sensitivity (0.93), confidence rating (0.64) and interobserver agreement for 18F-FDG PET compared with eASL. The same was true for assigning a specific differential diagnosis (sensitivity: and 0.39 for 18F-FDG PET and eASL, respectively). Semiquantitative analyses revealed prototypical patterns for AD and FTD, with both higher volumes of abnormality and intensity differences on 18F-FDG PET.

CONCLUSION

In a direct head-to-head comparison on a simultaneous GE Signa PET/MR, 18F-FDG PET performed better compared with ASL in terms of sensitivity and reader confidence, as well as volume and intensity of abnormalities. However, using pure semiquantitative analysis, similar diagnostic accuracy between the two modalities was obtained. Therefore, ASL may still serve as complement to neuroreceptor or protein deposition PET studies when a single simultaneous investigation is warranted.

Для цитирования: Ceccarini Jenny, Bourgeois Sophie, Van Weehaeghe Donatienne, Goffin Karolien, Vandenberghe Rik, Vandenbulcke Mathieu, Sunaert Stefan, Van Laere Koen. Direct prospective comparison of 18F-FDG PET and arterial spin labelling MR using simultaneous PET/MR in patients referred for diagnosis of dementia.. European journal of nuclear medicine and molecular imaging. 2020. DOI: 10.1007/s00259-020-04694-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.