MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2017.02.010

Медицинская библиотека · European journal of radiology · 2017

Intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injuries.

Wangensteen Arnlaug, Tol Johannes L, Roemer Frank W, Bahr Roald, Dijkstra H Paul, Crema Michel D, Farooq Abdulaziz, Guermazi Ali

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess and compare the intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injury.

METHODS

Male athletes (n=40) with clinical diagnosis of acute hamstring injury and MRI ≤5days were selected from a prospective cohort. Two radiologists independently evaluated the MRIs using standardised scoring form including the modified Peetrons grading system, the Chan acute muscle strain injury classification and the British Athletics Muscle Injury Classification. Intra-and interrater reliability was assessed with linear weighted kappa (κ) or unweighted Cohen's κ and percentage agreement was calculated.

RESULTS

We observed 'substantial' to 'almost perfect' intra- (κ range 0.65-1.00) and interrater reliability (κ range 0.77-1.00) with percentage agreement 83-100% and 88-100%, respectively, for severity gradings, overall anatomical sites and overall classifications for the three MRI systems. We observed substantial variability (κ range -0.05 to 1.00) for subcategories within the Chan classification and the British Athletics Muscle Injury Classification, however, the prevalence of positive scorings was low for some subcategories.

CONCLUSIONS

The modified Peetrons grading system, overall Chan classification and overall British Athletics Muscle Injury Classification demonstrated 'substantial' to 'almost perfect' intra- and interrater reliability when scored by experienced radiologists. The intra- and interrater reliability for the anatomical subcategories within the classifications remains unclear.

Для цитирования: Wangensteen Arnlaug, Tol Johannes L, Roemer Frank W, Bahr Roald, Dijkstra H Paul, Crema Michel D, Farooq Abdulaziz, Guermazi Ali. Intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injuries.. European journal of radiology. 2017. DOI: 10.1016/j.ejrad.2017.02.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.