DOI 10.1007/s00223-017-0307-y

Медицинская библиотека · Calcified tissue international · 2017

Evaluation of a New Fully Automated Assay for Plasma Intact FGF23.

Souberbielle Jean-Claude, Prié Dominique, Piketty Marie-Liesse, Rothenbuhler Anya, Delanaye Pierre, Chanson Philippe, Cavalier Etienne

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

Several FGF23 immunoassays are available. However, they are reserved for research purposes as none have been approved for clinical use. We evaluated the performances of a new automated assay for intact FGF23 on the DiaSorin Liaison platform which is approved for clinical use. We established reference values in 908 healthy French subjects aged 18-89 years, and measured iFGF23 in patients with disorders of phosphate metabolism and in patients with chronic kidney disease (CKD). Intra-assay CV was 1.04-2.86% and inter-assay CV was 4.01-6.3%. The limit of quantification was <10 ng/L. Serum iFGF23 concentrations were considerably lower than EDTA values highlighting the importance of using exclusively EDTA plasma. Liaison iFGF23 values were approximately 25% higher than Immutopics values. In the 908 healthy subjects, distribution of the Liaison iFGF23 values was Gaussian with a mean ± 2SD interval of 22.7-93.1 ng/L. Men had a slightly higher level than women (60.3 ± 17.6 and 55.2 ± 17.2 ng/L, respectively). Plasma iFGF23 concentration in 11 patients with tumour-induced osteomalacia, 8 patients with X-linked hypophosphatemic rickets, 43 stage 3a, 43 stage 3b, 43 stage 4, 44 stage 5 CKD patients, and 44 dialysis patients were 217.2 ± 144.0, 150.9 ± 28.6, 98.5 ± 42.0, 130.8 ± 88.6, 130.8 ± 88.6, 331.7 ± 468.2, 788.8 ± 1306.6 and 6103.9 ± 11,178.8 ng/L, respectively. This new iFGF23 assay available on a platform that already allows the measurement of other important parameters of the mineral metabolism is a real improvement for the laboratories and clinicians/researchers involved in this field.

Для цитирования: Souberbielle Jean-Claude, Prié Dominique, Piketty Marie-Liesse, Rothenbuhler Anya, Delanaye Pierre, Chanson Philippe, Cavalier Etienne. Evaluation of a New Fully Automated Assay for Plasma Intact FGF23.. Calcified tissue international. 2017. DOI: 10.1007/s00223-017-0307-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.