MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/2022.2.spine22143

Медицинская библиотека · Journal of neurosurgery. Spine · 2022

Longitudinal assessment of segmental motion of the cervical spine following total disc arthroplasty: a comparative analysis of devices.

Colman Matthew W, Zavras Athan G, Federico Vincent P, Nolte Michael T, Butler Alexander J, Singh Kern, Phillips Frank M

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Total disc arthroplasty (TDA) has been shown to be an effective and safe treatment for cervical degenerative disc disease at short- and midterm follow-up. However, there remains a paucity of literature reporting the differences between individual prosthesis designs with regard to device performance. In this study, the authors evaluated the long-term maintenance of segmental range of motion (ROM) at the operative cervical level across a diverse range of TDA devices.

METHODS

In this study, the authors retrospectively evaluated all consecutive patients who underwent 1- or 2-level cervical TDA between 2005 and 2020 at a single institution. Patients with a minimum of 6 months of follow-up and lateral flexion/extension radiographs preoperatively, 2 months postoperatively, and at final follow-up were included. Radiographic measurements included static segmental lordosis, segmental range of motion (ROM) on flexion/extension, global cervical (C2-7) ROM on flexion/extension, and disc space height. The paired t-test was used to evaluate improvement in radiographic parameters. Subanalysis between devices was performed using one-way ANCOVA. Significance was determined at p < 0.05.

RESULTS

A total of 85 patients (100 discs) were included, with a mean patient age of 46.01 ± 8.82 years and follow-up of 43.56 ± 39.36 months. Implantations included 22 (22.00%) M6-C, 51 (51.00%) Mobi-C, 14 (14.00%) PCM, and 13 (13.00%) ProDisc-C devices. There were no differences in baseline radiographic parameters between groups. At 2 months postoperatively, PCM provided significantly less segmental lordosis (p = 0.037) and segmental ROM (p = 0.039). At final follow-up, segmental ROM with both the PCM and ProDisc-C devices was significantly less than that with the M6-C and Mobi-C devices (p = 0.015). From preoperatively to 2 months postoperatively, PCM implantation led to a significant loss of lordosis (p < 0.001) and segmental ROM (p = 0.005) relative to the other devices. Moreover, a significantly greater decline in segmental ROM from 2 months postoperatively to final follow-up was seen with ProDisc-C, while segmental ROM increased significantly over time with Mobi-C (p = 0.049).

CONCLUSIONS

Analysis by TDA device brand demonstrated that motion preservation differs depending on disc design. Certain devices, including M6-C and Mobi-C, improve ROM on flexion/extension from preoperatively to postoperatively and continue to increase slightly at final follow-up. On the other hand, devices such as PCM and ProDisc-C contributed to greater segmental stiffness, with a gradual decline in ROM seen with ProDisc-C. Further studies are needed to understand how much segmental ROM is ideal after TDA for preservation of physiological cervical kinematics.

Для цитирования: Colman Matthew W, Zavras Athan G, Federico Vincent P, Nolte Michael T, Butler Alexander J, Singh Kern, Phillips Frank M. Longitudinal assessment of segmental motion of the cervical spine following total disc arthroplasty: a comparative analysis of devices.. Journal of neurosurgery. Spine. 2022. DOI: 10.3171/2022.2.spine22143.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.