Use of Silicone Tubes as Antiadhesion Devices in a Modified Two-Stage Flexor Tendon Reconstruction in Zone II: A Retrospective Study.

Li Yen-Wei, Ma Ching-Hou, Huang Hui-Kuang, Lin Kai-Jen, Wu Chin-Hsien, Tu Yuan-Kun

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study aimed to assess the outcome of a modified two-stage flexor tendon reconstruction using silicone tubes as antiadhesion devices while performing simultaneous tendon grafting.

METHODS

From April 2008 to October 2019, 16 patients (21 fingers) with zone II flexor tendon injuries, who sustained failed tendon repair or neglected tendon laceration, were treated by a modified two-stage flexor tendon reconstruction. The first stage of treatment comprised flexor tendon reconstruction with interposition of silicone tubes to minimize fibrosis and adhesion around the tendon graft; the second stage of treatment comprised silicone tube removal under local anesthesia.

RESULTS

The patient median age was 38 (range, 22-65) years. After a median follow-up period of 14 (range, 12-84) months, the median total active motion (TAM) of fingers was 220° (range, 150-250°). Excellent and good TAM ratings were identified in 71.4%, 76.2%, and 76.2% according to the Strickland, modified Strickland, and American Society for Surgery of the Hand (ASSH) evaluation systems, respectively. At follow-up, complications included superficial infections in two fingers of one patient whose silicone tube was removed 4 weeks postoperatively. The most common complication was a flexion deformity of the proximal interphalangeal joint (four fingers) and/or distal interphalangeal joint (nine fingers). The rate of failed reconstruction was higher in patients with preoperative stiffness and infection.

CONCLUSIONS

Silicone tubes are suitable antiadhesion devices, and the modified two-stage flexor tendon reconstruction technique is an alternative procedure with a shorter rehabilitation period for complicated flexor tendon injury, compared with current popular reconstructions. Preoperative stiffness and postoperative infection may compromise the final clinical outcome.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.

Для цитирования: Li Yen-Wei, Ma Ching-Hou, Huang Hui-Kuang, Lin Kai-Jen, Wu Chin-Hsien, Tu Yuan-Kun. Use of Silicone Tubes as Antiadhesion Devices in a Modified Two-Stage Flexor Tendon Reconstruction in Zone II: A Retrospective Study.. The Journal of hand surgery. 2023. DOI: 10.1016/j.jhsa.2023.01.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.