MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/vetsci12070682

Медицинская библиотека · Veterinary sciences · 2025

Finite Element Analysis of Stress Distribution in Canine Lumbar Fractures with Different Pedicle Screw Insertion Angles.

Zhou Ziyao, Shi Xiaogang, Peng Jiahui, Zhou Xiaoxiao, Yang Liuqing, Zhong Zhijun, Liu Haifeng, Peng Guangneng, Zheng Chengli, Zhang Ming

СтатьяПеревод в очереди

Аннотация

Pedicle screw fixation is a critical technique for stabilizing lumbar fractures in canines, yet the biomechanical implications of insertion angles remain underexplored. This study aims to identify optimal screw trajectories by analyzing stress distribution and deformation patterns in beagle lumbar segments (L6-L7) using finite element analysis (FEA). A 3D finite element model was reconstructed from CT scans of a healthy beagle, incorporating cortical/cancellous bone, intervertebral disks, and cartilage. Pedicle screws (2.4 mm diameter, 22 mm length) were virtually implanted at angles ranging from 45° to 65°. A 10 N vertical load simulated standing conditions. Equivalent stress and total deformation were evaluated under static loading. The equivalent stress occurred at screw-rod junctions, with maxima at 50° (11.73 MPa) and minima at 58° (3.25 MPa). Total deformation ranged from 0.0033 to 0.0064 mm, with the highest at 55° and the lowest at 54°. The 58° insertion angle demonstrated optimal biomechanical stability with minimal stress concentration, with 56-60° as a biomechanically favorable range for pedicle screw fixation in canine lumbar fractures, balancing stress distribution and deformation control. Future studies should validate these findings in multi-level models and clinical settings.

Для цитирования: Zhou Ziyao, Shi Xiaogang, Peng Jiahui, Zhou Xiaoxiao, Yang Liuqing, Zhong Zhijun, Liu Haifeng, Peng Guangneng, Zheng Chengli, Zhang Ming. Finite Element Analysis of Stress Distribution in Canine Lumbar Fractures with Different Pedicle Screw Insertion Angles.. Veterinary sciences. 2025. DOI: 10.3390/vetsci12070682.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.