A patient with juvenile rheumatoid arthritis and chronic iritis is reported with intraocular pressure near 30 mm Hg and previous episodes of intraocular pressure as high as 50 mm Hg despite maximally tolerated medical therapy. Because of the potential risk involved with a full-thickness filtration procedure, it was decided that a nonpenetrating deep sclerectomy would be appropriate, followed by placement of a collagen glaucoma drainage device to maintain aqueous outflow. Immediately postoperatively, intraocular pressure was stabilized. At 24 months postoperatively, intraocular pressure was well controlled at 15 mm Hg with patient receiving only Lotemax. No significant complications were noted at any point in the postoperative course. Because of the patient's predisposition for serious complications frequently associated with trabeculectomy, nonpenetrating deep sclerectomy with the collagen glaucoma drainage device was an effective alternative for this patient.

Для цитирования: Price Francis W, Ziemba Steven L. Placement of a collagen glaucoma drainage device to control intraocular pressure and chronic iritis secondary to juvenile rheumatoid arthritis.. Ophthalmic surgery and lasers. 2002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.