MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2478/prilozi-2026-0025

Медицинская библиотека · Prilozi (Makedonska akademija na naukite i umetnostite. Oddelenie za medicinski nauki) · 2026

Functional Impairment in Aseptic Loosening of Total Hip Arthroplasty: The Role of Defect Severity, Osteolysis Burden, and Fixation Type.

Talevski Darko, Nancheva Jasminka, Ciriviri Jasmin, Nestorovski Zoran, Vangelovska Zorica, Ciriviri Dusko, Stefanovski Kuzman, Aleksandra Jovanova

СтатьяПеревод в очереди

Аннотация

Background

Aseptic loosening remains a major indication for revision total hip arthroplasty. The relationship between functional impairment and structural disease burden is clinically relevant but not fully quantified.

Objective

To evaluate whether Harris Hip Score is associated with Paprosky defect severity, computed tomography based osteolysis volume, anatomical osteolysis distribution, and fixation type in patients revised for aseptic loosening.

Methods

Sixty patients revised for aseptic loosening were analyzed, including 30 cemented and 30 cementless implants. Harris Hip Score was evaluated in relation to Paprosky defect type, femoral, acetabular, and total osteolysis volumes, and Gruen and DeLee and Charnley zone involvement. Multivariable linear regression, interaction models, sensitivity analyses, and influence diagnostics were performed.

Results

Harris Hip Score was lower in cementless than cemented implants (35.4 ± 11.42 versus 57.95 ± 9.24; p < 0.001). Functional score declined progressively with increasing Paprosky severity. In the primary adjusted model, Paprosky score was independently associated with lower Harris Hip Score (B = -6.18; p < 0.001), while cementless fixation remained independently associated with lower score (B = -17.01; p < 0.001). The model explained 88.0% of Harris Hip Score variation. Adding osteolysis-volume variables minimally improved model performance. Sensitivity analyses confirmed the stability of the main predictors.

Conclusions

Functional impairment in aseptic loosening after total hip arthroplasty is most strongly associated with Paprosky defect severity and fixation type. Computed tomography based osteolysis volume and anatomical zone mapping provide complementary structural information for revision planning.

Для цитирования: Talevski Darko, Nancheva Jasminka, Ciriviri Jasmin, Nestorovski Zoran, Vangelovska Zorica, Ciriviri Dusko, Stefanovski Kuzman, Aleksandra Jovanova. Functional Impairment in Aseptic Loosening of Total Hip Arthroplasty: The Role of Defect Severity, Osteolysis Burden, and Fixation Type.. Prilozi (Makedonska akademija na naukite i umetnostite. Oddelenie za medicinski nauki). 2026. DOI: 10.2478/prilozi-2026-0025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.