DOI 10.1016/j.talanta.2026.130258
A dual-response near-infrared fluorescent probe for hypochlorite and viscosity detection in ferroptosis and rheumatoid arthritis model.
Аннотация
In rheumatoid arthritis (RA), ferroptosis and reactive oxygen species (ROS) form a pathological cycle where ROS accumulation both drives and signals ferroptosis, making ROS detection critical for assessing oxidative damage. However, conventional single-function ROS fluorescent probes suffer from significant limitations in sensitivity, accuracy, and dynamic monitoring capability, which constrain an in-depth understanding of the role of this vicious cycle in RA pathogenesis. Herein, we report a rationally constructed dual-responsive near-infrared fluorescence probe, DTPD, capable of concurrently detecting fluctuations in viscosity and hypochlorite (HClO) concentrations. As microviscosity increases, DTPD manifests a linearly augmented emission in the green channel (λex = 375 nm), thereby operating through an off-on fluorescence switching mechanism ideal for quantitative viscosity detecting. Simultaneously, oxidative activation of the probe by HClO induces a pronounced bathochromic shift accompanied by enhanced red fluorescence, establishing a ratiometric quantification modality (λex = 436 nm) for precise HClO sensing. Such dual-lock-controlled fluorescence response, integrating orthogonal off-on and ratiometric signaling paradigms, affords high-fidelity simultaneous imaging of both analytes with minimal crosstalk. Benefiting from its optimized photophysical properties, DTPD enables real-time tracking of viscosity and HClO dynamics in living cells, revealing their dynamic interplay during inflammatory progression. Moreover, DTPD visualizes the dynamic changes of HClO and viscosity during ferroptosis and successfully captures the alleviation of pathological progression in RA model mice following treatment with a ferroptosis inhibitor. This study provides new mechanistic insights into the role of ferroptosis in rheumatoid arthritis and offers a potential avenue for therapeutic intervention.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.