MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jare.2026.04.013

Медицинская библиотека · Journal of advanced research · 2026

Multicenter deep learning for multi-abnormality screening on hip radiographs: development, external validation, and assisted reader study.

Xu Shenghao, Guo Chaohui, Xu Qibo, Zuo Jianlin, Yang Min, Chen Bo, Li Shihuai, Xiao Jianlin, Tang Xiongfeng, Qin Yanguo

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Hip abnormalities are a major cause of pain and functional impairment, yet missed diagnoses remain common due to high clinical workloads and interobserver variability. Existing deep learning (DL) models predominantly target single pathologies, limiting their utility for comprehensive screening.

OBJECTIVES

To develop and validate a DL model for simultaneous screening of multiple hip conditions using a large, multicenter dataset of pelvic radiographs.

METHODS

A ResNet-50-based model was trained and internally validated using data from two hospitals (25,908 hips) with enhancements (convolutional block attention module, generalized mean pooling, and class-balanced focal loss) for classifying eight categories: normal, hip osteoarthritis, osteonecrosis of the femoral head, femoral neck fracture (FNF), intertrochanteric fracture (ITF), developmental dysplasia of the hip, total hip arthroplasty, and metallic internal fixation. External validation was performed on 4,600 hips from a third hospital. Model performance was compared with that of six orthopedic surgeons of varying seniority, and a two-phase reader study assessed diagnostic performance with and without model assistance; non-inferiority was prespecified at a 5% margin for accuracy and macro-F1.

RESULTS

On the internal test set, the model achieved 93.93% accuracy (95% confidence interval [CI]: 93.26-94.56), macro-AUC 0.99, and macro-F1 90.66% (95% CI: 88.83-92.14). On the external test set, accuracy was 90.11% (95% CI: 89.28-90.98), with macro-AUC 0.99 and macro-F1 87.29% (95% CI: 86.02-88.56). Sensitivity was high for acute injuries (FNF: 95.61% [95% CI: 92.82-98.17]; ITF: 95.31% [95% CI: 90.36-98.94]). The model outperformed residents and attendings (P < 0.001) and was non-inferior to deputy chiefs. Assistance improved surgeon accuracy (gains: 3.93%-11.33%) and inter-rater agreement (κ: from 0.52-0.88 to 0.69-0.88).

CONCLUSIONS

We developed and externally validated a DL model for automated screening of multiple common hip abnormalities. The system is well-suited for triage workflows by flagging high-risk cases for expedited review. Additionally, it may function as a supportive second reader in high-volume or resource-limited settings.

Для цитирования: Xu Shenghao, Guo Chaohui, Xu Qibo, Zuo Jianlin, Yang Min, Chen Bo, Li Shihuai, Xiao Jianlin, Tang Xiongfeng, Qin Yanguo. Multicenter deep learning for multi-abnormality screening on hip radiographs: development, external validation, and assisted reader study.. Journal of advanced research. 2026. DOI: 10.1016/j.jare.2026.04.013.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.