Advantages of Combined Use of Claw Hooks and Sublaminar Wires as the Upper Foundation of Long Fixation from the Thoracic Spine to the Pelvis in Osteoporotic Cases: A Finite Element Analysis of Proximal Junction Stress.

Kozaki Takuhei, Shimizu Takachika, Murata Akimasa, Nakanishi Ryuichiro, Kozaki Takahiro, Yamamoto Ei, Tsutsui Shunji, Kawakami Mamoru, Yamada Hiroshi

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

This study aimed to compare the biomechanical stress at the proximal junctional aspect between the conventional pedicle screw (PS) fixation (PSF) and the low PS density fixation (LPF) method.

METHODS

This study involved 10 patients, half of whom have non-osteoporosis and the other half have osteoporosis. We made two types of intact models (one is from the upper thoracic-to-pelvis model, and the other is from the lower thoracic-to-pelvis model). From the intact models, we constructed two kinds of fusion models: (1) PSF and (2) LPF. The LPF method was as follows: The claw hooks (the combination of the down-going transverse process hooks and facet hooks) were set at the upper instrumented vertebra (UIV) and sublaminar wires at the thoracic spine and PSs at the lumbo-pelvis.

RESULTS

Upper thoracic to pelvis fixation model In non-osteoporosis, no significant difference between the PSF and LPF is found. In osteoporosis, the von Mises stresses of the vertebra body at UIV, UIV+1, and disc were significantly lower in LPF than in PSF. Lower thoracic-to-pelvis fixation model In non-osteoporosis, the average von Mises stress of the vertebral body at UIV+1 and the maximum stress at UIV were lower in LPF than in PSF; however, no significant difference was found in the others. In osteoporosis, the von Mises stress was significantly lower in LPF than in PSF.

CONCLUSIONS

The claw hooks stabilized the vertebra body at UIV firmly, and sublaminar wires reduced load translation from the fixed spine.

Для цитирования: Kozaki Takuhei, Shimizu Takachika, Murata Akimasa, Nakanishi Ryuichiro, Kozaki Takahiro, Yamamoto Ei, Tsutsui Shunji, Kawakami Mamoru, Yamada Hiroshi. Advantages of Combined Use of Claw Hooks and Sublaminar Wires as the Upper Foundation of Long Fixation from the Thoracic Spine to the Pelvis in Osteoporotic Cases: A Finite Element Analysis of Proximal Junction Stress.. Spine surgery and related research. 2024. DOI: 10.22603/ssrr.2024-0169.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.