Secondary Sternal Closure With Titanium Plate Fixation After Bilateral Lung Transplantation.

Vale Flávia Fiuza de Andrade, Lucas Dos Santos Samuel, Pola Dos Reis Flavio, Fernandes Lucas Matos, Abdalla Luis Gustavo, Campos Silvia Vidal, Pêgo Fernandes Paulo Manuel

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Transverse thoracosternotomy (clamshell incision) provides wide exposure of thoracic anatomical structures and is commonly used in bilateral lung transplantation. However, it is associated with a significant risk of mechanical sternal complications. Conventional closure with stainless steel wires has reported complication rates of 20%-40%, prompting the development of alternative sternal closure strategies.

METHODS

This retrospective, single-center study included patients who underwent bilateral lung transplantation between January 2020 and December 2024. A total of 131 transplants were performed, 7 patients required reoperation for sternal complications. In all cases, surgical access was obtained via a clamshell incision with transverse sternotomy. Primary sternal closure was performed using 3 interrupted stainless steel wire sutures. In cases of sternal complications, secondary closure was achieved using a rigid titanium fixation system. Demographic data, clinical characteristics, perioperative variables, and outcomes were analyzed

RESULTS

Only 1 patient had pre-transplant colonization. All donor cultures were positive, with Staphylococcus aureus isolated in 6 cases. 3 patients required extracorporeal support, 2 of whom were listed under high-urgency status; 1 required intensive care with an open chest on ECMO. Four patients were reoperated on for sternal osteomyelitis, and 3 for mechanical instability or persistent pain. All patients achieved successful sternal realignment and symptom resolution, with no fixation-related complications.

CONCLUSION

Rigid titanium plate fixation is a safe and effective option for secondary sternal closure after bilateral lung transplantation and represents a promising strategy to reduce clamshell-related sternal complications.

Для цитирования: Vale Flávia Fiuza de Andrade, Lucas Dos Santos Samuel, Pola Dos Reis Flavio, Fernandes Lucas Matos, Abdalla Luis Gustavo, Campos Silvia Vidal, Pêgo Fernandes Paulo Manuel. Secondary Sternal Closure With Titanium Plate Fixation After Bilateral Lung Transplantation.. Transplantation proceedings. 2026. DOI: 10.1016/j.transproceed.2026.07.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.