DOI 10.13107/jocr.2026.v16.i08.7896
Augmentation Plating with Intramedullary Nailing for Aseptic Long Bone Non-union: A Prospective Observational Study of Clinical, Radiological, and Functional Outcomes.
Аннотация
INTRODUCTION
Non-union of long bone fractures after intramedullary nailing (IMN) remains a demanding clinical challenge. Augmentation plating - applying a supplementary plate over the retained nail - offers superior rotational control without the morbidity of nail extraction. This prospective study evaluated clinical, radiological, and functional outcomes of this technique for aseptic femoral and tibial non-unions.
MATERIALS AND
METHODS
Thirty patients with aseptic diaphyseal non-union of the femur or tibia underwent augmentation plating with selective autologous bone grafting (April 2024-September 2025). Radiological healing was assessed by the modified Radiographic Union Score for Tibia (mRUST). Functional recovery was quantified by the lower extremity functional scale (LEFS) and Wu's criteria.
RESULTS
All 30 patients (17 femoral, 13 tibial) achieved radiological union, representing a 100% union rate. Mean time to union was 6.23 ± 0.82 months (range 5-8 months). Femoral non-unions healed significantly faster than tibial non-unions (5.88 vs. 6.69 months; P = 0.005). The mean mRUST score improved from 5.17 ± 0.79 preoperatively to 15.33 ± 0.84 at final follow-up (P < 0.001). Mean LEFS improved from 31.77 ± 3.39 to 76.60 ± 3.77 (P < 0.001). By Wu's criteria, 60% achieved excellent and 30% achieved good results; no patient had a poor outcome. The complication rate was 10%, comprising two superficial infections managed conservatively and one deep infection managed with debridement, antibiotics, and implant retention; fracture union was achieved in all three.
CONCLUSION
Augmentation plating with selective autologous bone grafting delivers 100% union rates with predictable healing timelines and near-normal functional recovery in aseptic femoral and tibial non-unions. The technique is mechanically sound, biologically preserving, and operatively efficient - making it a reliable first-choice revision strategy in this clinical setting.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.