MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ksa.12540

Медицинская библиотека · Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2024

Zero incidence of culture-positive septic arthritis and low infection rate following ACLR with all-soft tissue quadriceps tendon autograft: An analysis of 1053 cases.

Seilern Und Aspang Jesse, Kopriva John, Garry Jason, Haley Rebecca, Collins Austin, Lamplot Joseph D, Slone Harris, Xerogeanes John W

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the infection rate following anterior cruciate ligament reconstruction (ACLR) using all-soft tissue quadriceps tendon (ASTQT) autograft.

METHODS

All primary ASTQT autograft ACLRs within a single surgeon's prospectively collected database from 2011 to 2021 were retrospectively reviewed. No topical antibiotics were administered and no graft-soaking with antibiotics was performed during the study period. Patients who underwent multiligament knee reconstruction or a cartilage restoration procedure were excluded. Patients who underwent a subsequent procedure, including irrigation and debridement (I&D) of the knee joint, were included. Case-specific data, including fluid culture analysis, antibiotics (type, route of administration and duration), time to debridement and method of debridement, were collected. Descriptive statistics were utilized to analyze demographics, incidence and possible association between the need for I&D and concomitant meniscus surgery.

RESULTS

Out of 1053 cases (mean age: 20.2 ± 6.3, 44.6% female), four patients (0.38%) (mean age: 18.5 ± 4.0, 25% female) underwent subsequent I&D (arthroscopic I&D only [n = 1], graft harvest site I&D only [n = 1], combined graft harvest site and arthroscopic I&D [n = 1] and tibia wound and arthroscopic I&D [n = 1]). There was no significant difference with regard to demographics. No joint fluid cultures returned positive; one wound culture returned positive for Methicillin-susceptible Staphylococcus aureus from their graft harvest site. The time to I&D ranged from 18 to 23 days. Concomitant meniscectomy or meniscal repair was not associated with requiring surgical I&D. All patients who underwent I&D were prescribed antibiotics for a minimum of 10 days and a maximum of 31 days (mean: 16.25 days). Three patients (75%) who underwent I&D ultimately returned to sport. One patient was lost to follow-up. ACL grafts were retained in all patients.

CONCLUSION

The incidence of culture-positive septic arthritis following ASTQT autograft ACLR is 0%, while the overall need for I&D of 0.38% is low and not related to concomitant meniscal procedures or patient-specific factors.

LEVEL OF EVIDENCE: Level IV.

Для цитирования: Seilern Und Aspang Jesse, Kopriva John, Garry Jason, Haley Rebecca, Collins Austin, Lamplot Joseph D, Slone Harris, Xerogeanes John W. Zero incidence of culture-positive septic arthritis and low infection rate following ACLR with all-soft tissue quadriceps tendon autograft: An analysis of 1053 cases.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2024. DOI: 10.1002/ksa.12540.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.