MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.kint.2025.05.018

Медицинская библиотека · Kidney international · 2025

Evaluation of methodologies in anti-nephrin autoantibody detection.

Liu Pan, Liu Shuping, Dalal Vidhi, Lane Jerome, Cravedi Paolo, Campbell Kirk, Angeletti Andrea, Xie Xinfang, Gessaroli Elisa, Forte Eleonora, Gallon Lorenzo, Jin Jing

СтатьяСравнительное исследованиеОценочное исследованиеПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

INTRODUCTION

Recent studies discovered the prominent presence of anti-nephrin autoantibodies in minimal change disease (MCD) and focal segmental glomerulosclerosis (FSGS). However, widely different and often unconventional autoantibody detection methods were used in these studies, making it challenging to standardize anti-nephrin antibody detection and quantification across different studies.

METHODS

Here, we compare methods of conventional ELISA, immunoprecipitation (IP)-based on-beads ELISA, immunoprecipitation-Western blotting (IP-WB), and cell- and tissue-based immunofluorescence staining with two cohorts totaling 169 patients and control individuals.

RESULTS

Different assay methods and antigen preparations led to method-specific false-positive and false-negative results. In general, high-quality antigens produced in human cells, combined with IP-based assays, yielded the most robust and reliable results. Among 63 and 24 samples from patients with FSGS or MCD, respectively, two patients with FSGS showed strong antibody signals in both ELISA-based assays and IP-WB, while approximately half of patients with MCD had weak signals detectable only by IP-WB.

CONCLUSIONS

These findings highlight the importance of standardizing antibody detection methods.

Для цитирования: Liu Pan, Liu Shuping, Dalal Vidhi, Lane Jerome, Cravedi Paolo, Campbell Kirk, Angeletti Andrea, Xie Xinfang, Gessaroli Elisa, Forte Eleonora, Gallon Lorenzo, Jin Jing. Evaluation of methodologies in anti-nephrin autoantibody detection.. Kidney international. 2025. DOI: 10.1016/j.kint.2025.05.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.