MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/17531934261483321

Медицинская библиотека · The Journal of hand surgery, European volume · 2026

Biomechanical comparison of suture materials across a bone tunnel edge.

Basseri Benjamin, Shamritsky David, Escalera Cristian, Wolfe Scott W

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Wrist reconstructive procedures commonly use synthetic materials passed through transosseous tunnels to stabilize the carpus. This experimental study compared the tensile mechanical properties of common sutures and synthetic tapes across a bone tunnel edge. We hypothesized that failure would primarily occur at the cortical bone edge owing to abrasion at the suture-bone interface and that increasing strand number would increase construct stiffness and decrease failure.

METHODS

Five suture materials (SutureTape, LabralTape, FiberTape, Ethibond, and Mersilene) were tested in one-, two- and four-strand configurations, with 12 constructs per group. Constructs were passed through a 2.5 mm transverse tibial bone tunnel and secured to a servohydraulic testing apparatus with knotless fixation. Testing simulated physiologic scapholunate ligament loading with 1000 cycles from 0 to 100 N at 1.5 Hz followed by ramp loading to 300 N. One-way ANOVA with Tukey post hoc analysis (α = 0.05) evaluated load at failure and percentage elongation.

RESULTS

Single-strand SutureTape, Mersilene and Ethibond demonstrated greater elongation at 100 N than single-strand LabralTape and FiberTape (p < 0.001). Mersilene and Ethibond elongated significantly more than SutureTape. Increasing strand number decreased elongation, although not proportionally to the number of strands. Single-strand Ethibond and Mersilene had the highest failure rates and lowest failure loads. No single- or double-strand LabralTape or FiberTape constructs failed at the bone tunnel edge.

CONCLUSION

Synthetic suture and tape constructs demonstrated differing mechanical properties and failure modes across a bone tunnel edge. Material selection and strand configuration may influence construct stiffness, elongation, and failure risk for ligament reconstruction.

Для цитирования: Basseri Benjamin, Shamritsky David, Escalera Cristian, Wolfe Scott W. Biomechanical comparison of suture materials across a bone tunnel edge.. The Journal of hand surgery, European volume. 2026. DOI: 10.1177/17531934261483321.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.