MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fsurg.2026.1719831

Медицинская библиотека · Frontiers in surgery · 2026

Three-step fluoroscopy-guided percutaneous lumbar pedicle screw placement: a pilot study on technical feasibility, safety, and fluoroscopy reduction.

Wu Wei, Jia Ke, Kong Fanguo, Chen Chao

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Minimally invasive surgery has gained widespread popularity in clinical practice. Among spinal surgeries, percutaneous pedicle screw placement (PPS) is one of the most widely performed procedures. However, it necessitates high-frequency fluoroscopic guidance to ensure accuracy, resulting in substantial radiation exposure. Therefore, it is crucial to develop a technique that is fast, safe, and minimizes radiation exposure.

OBJECTIVE

We aimed to describe a novel three-step fluoroscopy-guided technique for PPS and preliminarily evaluate the technical feasibility, procedural efficiency, and short-term safety.

METHODS

This study prospectively enrolled consecutive patients who underwent PPS using either the three-step fluoroscopy-guided technique or the conventional method from December 2024 to February 2025, while data analysis was performed retrospectively. Data collected included operative time, fluoroscopy frequency, screw placement accuracy, and postoperative complications.

RESULTS

The three-step fluoroscopy-guided technique required an average of 4 ± 1.12 fluoroscopic exposures per screw, with an average screw placement time of 5.05 ± 0.923 min. In contrast, the conventional method required an average of 18.33 ± 2.89 fluoroscopic exposures per screw and an average placement time of 15.84 ± 4.11 min. And no significant complications, such as neural or vascular injuries, were reported.

CONCLUSION

This pilot study suggests that the three-step fluoroscopy-guided PPS technique is technically feasible and may reduce fluoroscopy usage while maintaining short-term procedural safety, making it a feasible and efficient alternative that warrants further validation in larger cohorts.

Для цитирования: Wu Wei, Jia Ke, Kong Fanguo, Chen Chao. Three-step fluoroscopy-guided percutaneous lumbar pedicle screw placement: a pilot study on technical feasibility, safety, and fluoroscopy reduction.. Frontiers in surgery. 2026. DOI: 10.3389/fsurg.2026.1719831.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.