Is High-Flexion Total Knee Arthroplasty a Valid Concept? Bilateral Comparison With Standard Total Knee Arthroplasty.
Аннотация
BACKGROUND
The purpose of this study was to determine whether the high-flexion total knee prosthesis significantly improves knee flexion in vivo.
METHODS
Forty-four patients undergoing same-day bilateral total knee arthroplasty for primary osteoarthritis of both knees were randomized to receive a standard posterior-stabilized knee prosthesis (P.F.C. Sigma; DePuy Johnson & Johnson, Warsaw, IN) in one knee and a high-flexion concept posterior-stabilized knee prosthesis (LOSPA; Corentec, Inc, Seoul, Korea) in the other knee and were followed up for 2 years postoperatively.
RESULTS
The mean postoperative range of motion was 128.8° (range, 100°-144°) in the LOSPA group and 128.5° (range, 100°-142°) in the P.F.C. Sigma group (P = .744). There were no significant differences in the postoperative mean Knee Society score and Western Ontario and McMaster Universities Osteoarthritis Index score between the LOSPA and P.F.C. Sigma groups (P = .839 and P = .972, respectively).
CONCLUSION
Despite theoretical range of motion advantages of high-flexion prosthesis, there were no group differences with regard to range of motion, clinical outcomes, and the incidence of radiolucent lines at final follow-up assessment.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.