MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-012-2324-x

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2012

A retrospective study of congenital osseous anomalies at the craniocervical junction treated by occipitocervical plate-rod systems.

Ding Xianjun, Abumi Kuniyoshi, Ito Manabu, Sudo Hideki, Takahata Masahiko, Nagahama Ken, Iwata Akira

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the effectiveness of posterior occipitocervical reconstruction using the anchors of cervical pedicle screws and plate-rod systems for patients with congenital osseous anomalies at the craniocervical junction.

METHODS

Twenty patients with congenital osseous lesions who underwent posterior occipitocervical fusion using the anchors of cervical pedicle screws and plate-rod systems for reduction and fixation from 1996 to 2009 were reviewed. The lesions included os odontoideum, occipitalization of the atlas, congenital C2-3 fusion, congenital atlantoaxial subluxation, congenital basilar invagination and combined anomalies. The clinical assessment and the measurements of the images were performed preoperatively, postoperatively and at most recent follow-up.

RESULTS

The combined deformity of flexion of the occipitoatlantoaxial complex and invagination of the odontoid process associated with congenital osseous lesions at the craniocervical junction was corrected by application of combined forces of extension and distraction between the occiput and the cervical pedicle screws. Preoperative myelopathy improved in 94.7% patients. The mean Ranawat value, Redlund-Johnnell value, atlantodental distance, occiput (O)-C2 angle, and C2-C7 lordosis angle improved postoperatively and was sustained at most recent follow-up. The mean cervicomedullary angle improved from 129.3° preoperatively to 153.3° postoperatively. The mean range of motion at the lower adjacent motion segment remained unchanged at most recent follow-up. The fusion rate was 95%.

CONCLUSIONS

The results of the present study indicate that posterior occipitocervical reconstruction using the anchors of cervical pedicle screws and plate-rod systems is an effective technique for treatment of deformities and/or instability caused by congenital osseous anomalies at the craniocervical junction.

Для цитирования: Ding Xianjun, Abumi Kuniyoshi, Ito Manabu, Sudo Hideki, Takahata Masahiko, Nagahama Ken, Iwata Akira. A retrospective study of congenital osseous anomalies at the craniocervical junction treated by occipitocervical plate-rod systems.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2012. DOI: 10.1007/s00586-012-2324-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.