Radiation Exposure to the Sacroiliac Joint From Low-Dose CT Compared With Radiography.
Аннотация
OBJECTIVE
The primary objective of this study was to estimate the effective dose delivered to the sacroiliac joint (SIJ) from low-dose (LD) CT compared with that from radiography. Secondary objectives included evaluation of diagnostic quality of LD CT of the SIJ and development of a clinical protocol for LD CT of the SIJ.
MATERIALS AND
METHODS
Data from 36 patients (19 women, 17 men) undergoing LD CT for suspected renal colic were analyzed. Two effective dose estimates were calculated: one for the SIJ and another for an extended region from the iliac crest to 1 cm below the SIJ. Thirty-six anteroposterior pelvic and 36 SIJ view radiographs were age-, sex-, and body width-matched to CT scans. Effective dose from radiography was estimated using the method described in International Commission on Radiologic Protection Publication 60.
RESULTS
Maximum effective dose to the SIJ from LD CT was less than 1 mSv in all cases, with a mean ± SD of 0.42 ± 0.18 mSv (range, 0.14-0.83 mSv), whereas mean dose to the extended region was 0.57 ± 0.24 mSv (range, 0.19-1.11 mSv). Mean dose from SIJ radiographs was 0.15 ± 0.10 mSv (range, 0.07-1.38 mSv), and mean dose from a single pelvic radiograph was 0.09 ± 0.06 mSv (range, 0.04-0.37 mSv). All CT studies were of diagnostic quality for assessment of the SIJ.
CONCLUSION
LD CT of the SIJ can be consistently performed with an effective radiation dose of less than 1 mSv. Because reliability and sensitivity of radiography for sacroiliitis is poor, we recommend that LD CT replace radiography for dedicated evaluation of the SIJ.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.