MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fsurg.2024.1308389

Медицинская библиотека · Frontiers in surgery · 2024

Using the pedicle screw-U rod system for the treatment of double-level lumbar spondylolysis and isthmic spondylolisthesis.

Jiang Jinghao, Lin Tao, Chen Xia, Gao Rui, Zhou Xuhui

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to evaluate the efficacy of the pedicle screw-U rod system in treating double-level lumbar spondylolysis with or without spondylolisthesis.

METHODS

A retrospective study was conducted. Twenty-six patients were included in this study and followed up at 3, 6, and 12 months. Patients without spondylolisthesis were treated with double U-shaped rods (group I), and patients with spondylolisthesis were treated with a lengthened U-shaped rod (group II). Japanese Orthopedic Association (JOA) scores, Oswestry disability index (ODI) scores, disc range of motion (ROM), intervertebral space height of fixed levels and adjacent levels, and grading the degeneration of adjacent segmental intervertebral discs were evaluated preoperatively and postoperatively.

RESULTS

JOA and ODI scores improved significantly at 3 months both in groups I and II. The average bone grafting healing time was 6.1 ± 3.1 months for group I and 6 ± 2.8 months for group II. The intervertebral space heights of L4/L5 and L5/S1 were improved significantly at the final follow-up (p < 0.05 for both groups). Surgical segmental and adjacent segmental ROM had no significant change at the final follow-up, in comparison with data preoperatively (p > 0.05). No significant changes of intervertebral space height (L3/L4) and grading of intervertebral disc degeneration were noted before and after surgery (p = 0.141 and 0.484, respectively).

CONCLUSIONS

The pedicle screw-U rod system provided advantages of being easy in repairing symptomatic double-level lumbar spondylolysis. This technique improved disabilities of patients, preserved the lumbar spine ROM, and delayed the degeneration of adjacent segments.

Для цитирования: Jiang Jinghao, Lin Tao, Chen Xia, Gao Rui, Zhou Xuhui. Using the pedicle screw-U rod system for the treatment of double-level lumbar spondylolysis and isthmic spondylolisthesis.. Frontiers in surgery. 2024. DOI: 10.3389/fsurg.2024.1308389.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.