Медицинская библиотека · Coronary artery disease · 2026

The perforation triad as a recognition-and-response pattern for balloon- or stent-related Ellis II-III coronary artery perforation during percutaneous coronary intervention.

Acar Emrah, Acar Melike, Dönmez İbrahim, İzci Servet, Güneş Yilmaz, İzgi İbrahim Akin, Kirma Cevat

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Coronary artery perforation (CAP) is a rare but potentially catastrophic complication of percutaneous coronary intervention (PCI). We describe a prespecified candidate recognition pattern - the perforation triad - that may help operators identify an evolving perforation during inflation.

METHODS

In this single-center retrospective matched case-control study, 9865 PCI procedures performed between 2020 and 2025 were screened. Forty-one balloon- or stent-related Ellis II-III CAP cases (0.42%) were matched 1: 1 by age, sex, American College of Cardiology/American Heart Association lesion class, and rotational atherectomy use with uncomplicated PCI controls, each contributing one stage-matched index inflation. The triad - chest or back pain during inflation, abrupt balloon-waist disappearance without balloon rupture, and ventricular extrasystole temporally linked to inflation - was prespecified before data abstraction and adjudication. Prespecified descriptive analyses covered the three components, their pairwise combinations, and component-count thresholds; no threshold optimization was undertaken.

RESULTS

Among CAP cases, components were present in 78.0, 85.4, and 73.2%, respectively; the complete triad in 28 of 41 cases (68.3%; 95% confidence interval: 51.9-81.9) and in 0 of 41 selected control inflations. Control inflations meeting the pattern fell as more components were required (≥1, 20 of 41; ≥2, 10 of 41; triad, 0 of 41), with case-level sensitivity of 87.8, 80.5, and 68.3%. Tamponade requiring drainage occurred in 29.3%, and in-hospital mortality was 7.3%.

CONCLUSION

The perforation triad is a plausible recognition pattern for balloon- or stent-related Ellis II-III CAP. Because of retrospective sampling, selected controls, and incorporation bias, it should not be interpreted as a validated diagnostic rule or as evidence of real-world specificity; prospective inflation-level validation is required.

Для цитирования: Acar Emrah, Acar Melike, Dönmez İbrahim, İzci Servet, Güneş Yilmaz, İzgi İbrahim Akin, Kirma Cevat. The perforation triad as a recognition-and-response pattern for balloon- or stent-related Ellis II-III coronary artery perforation during percutaneous coronary intervention.. Coronary artery disease. 2026. DOI: 10.1097/mca.0000000000001673.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.