MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.k.01363

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2012

Risk of revision for fixed versus mobile-bearing primary total knee replacements.

Namba Robert S, Inacio Maria C S, Paxton Elizabeth W, Ake Christopher F, Wang Cunlin, Gross Thomas P, Marinac-Dabic Danica, Sedrakyan Art

Сравнительное исследованиеСтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

BACKGROUND

Mobile-bearing total knee arthroplasty prostheses were developed to reduce wear and revision rates; however, these benefits remain unproven. The purposes of this study were to compare the short-term survivorship and to determine risk factors for revision of mobile-bearing and fixed-bearing total knee replacements.

METHODS

A prospective cohort study of primary total knee arthroplasties performed from 2001 to 2009 was conducted with use of a community total joint replacement registry. Patient characteristics and procedure details were identified. Cox regression models were used. Bearing type was investigated as a risk factor for revision while adjusted for other risk factors such as age, American Society of Anesthesiologists (ASA) score, body mass index, sex, race, diagnosis, bilateral procedures, cruciate-retaining versus posterior-stabilized components, surgical approach, fixation, patellar resurfacing, hospital and surgeon volumes, and fellowship training.

RESULTS

The study cohort consisted of 47,339 total knee arthroplasties, with 62.6% of the procedures in women. Fixed bearings were used in 41,908 knees (88.5%) and mobile bearings in 4830 (10.2%). Rotating-platform designs were used in all mobile-bearing total knee arthroplasties (3112 had a Rotating-Platform Press-Fit Condylar posterior-stabilized design; 1053, a Low Contact Stress [LCS] design; and 665, a Rotating-Platform Press-Fit Condylar cruciate-retaining design). Patients who received fixed-bearing total knee arthroplasty systems were older (mean age, 68.1 years) than those who received mobile-bearing total knee arthroplasty systems (mean age, 62.2 years); the difference was significant (p < 0.001). Overall, 515 knees (1.1%) were revised for reasons other than infection. The survival rate was 97.8% (95% confidence interval [CI], 97.4% to 98.0%) at 6.7 years. The adjusted risk of aseptic revision for the LCS total knee replacements was 2.01 times (95% CI, 1.41 to 2.86) higher than that for fixed-bearing total knee replacements (p < 0.001).There was no significant revision risk for the other mobile-bearing total knee arthroplasty systems. There was no association with surgeon and hospital case volumes and the risk of revision total knee arthroplasty.

CONCLUSIONS

Our study suggests the benefit of potential long-term wear reduction with the LCS implant may not be realized in a community-based setting, where a variety of surgical skills, surgical experience, and diverse patient demographic factors may affect early outcomes.

LEVEL OF EVIDENCE: Therapeutic Level II.

Для цитирования: Namba Robert S, Inacio Maria C S, Paxton Elizabeth W, Ake Christopher F, Wang Cunlin, Gross Thomas P, Marinac-Dabic Danica, Sedrakyan Art. Risk of revision for fixed versus mobile-bearing primary total knee replacements.. The Journal of bone and joint surgery. American volume. 2012. DOI: 10.2106/jbjs.k.01363.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.