m+Medelevator.RU
← Поиск публикаций
Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026

Biomechanical effects of far-cortex over-penetration in locking plate fixation: A finite element study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Valiyev Natig, Zaman Cihan

Аннотация

This study quantified the biomechanical consequences of incremental far-cortex over-penetration at terminal locking screw positions in a locking compression plate construct using a validated three-dimensional finite element model of a femoral diaphyseal fracture (AO/OTA 32-A3). Four terminal screw engagement configurations were evaluated: unicortical fixation, fully contained bicortical fixation, 1-thread over-penetration (0.6 mm), and 3-thread over-penetration (1.8 mm). Axial compression (1000 N), torsional loading (±10 Nm), and cyclic dynamic loading (100-1000 N, 1 × 106 cycles) simulating the 8-week early postoperative period were applied. Model validation against published experimental data demonstrated agreement within 4% for all key biomechanical parameters. Fully contained bicortical fixation was the only configuration to remain below the predicted fatigue threshold, demonstrating the lowest peak von Mises stress (74.8 MPa) and a Miner's cumulative damage index of D = 0.291. Unicortical fixation (D = 1.103), 1-thread over-penetration (D = 1.362), and 3-thread over-penetration (D = 2.968) all exceeded the failure threshold (D ≥ 1.0). Under the loading conditions and material assumptions of the present finite element model, unicortical terminal fixation alone did not sustain simulated cyclic physiological loading during the pre-callus phase without exceeding the predicted fatigue damage threshold. These findings provide preliminary, model-dependent computational evidence suggesting that fully contained bicortical fixation may offer greater fatigue resistance, and that the biomechanical basis of current terminal screw placement guidelines warrants further experimental investigation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты