MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.msksp.2020.102202

Медицинская библиотека · Musculoskeletal science & practice · 2020

Establishing measurement properties in the assessment of inter-recti distance of the abdominal muscles in a postnatal women.

Benjamin Deenika R, Frawley Helena C, Shields Nora, Georgiou Chris, Taylor Nicholas F

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Diastasis of the rectus abdominis muscle is often evaluated in clinical practice but it is unknown which clinical method has the best measurement properties.

OBJECTIVE

The aim of this study was to determine: (i) the criterion validity of the callipers, tape measure and finger-width to evaluate the inter-recti distance of the abdominal muscles compared to ultrasound; and (ii) inter-rater and retest reliability of these methods.

DESIGN

Measurement study.

METHODS

Two physiotherapists assessed the inter-recti distance of rectus abdominis on 50 women postnatally using the three clinical methods. These measurements were compared to ultrasound and assessed for inter-rater and retest reliability.

RESULTS

Callipers had very good positive correlations with ultrasound (r = 0.85 to 0.99) and narrow limits of agreement (LOA) (<6 mm). Finger-width and tape measure had moderate to very good correlation with ultrasound (tape measure r = 0.82 to 0.98; finger-width r = 0.75 to 0.98) with wider limits of agreement (tape measure LOA <8 mm; finger-width LOA <18 mm). Callipers demonstrated excellent inter-rater (ICC = 0.80 to 0.99) and retest (ICC = 1.00) reliability. Inter-rater reliability testing was very good for tape measure (ICC = 0.80 to 0.97) and moderate to very good (ICC = 0.44 to 0.85) for finger-width. Retest reliability demonstrated very good reliability (ICC = 0.99 to 1.00) for both finger-width and tape measure. The largest inter-recti distances, strongest correlations and reliability were found at the level of the lower umbilicus.

CONCLUSION

Callipers, tape measure and finger-width are valid and reliable methods of measuring inter-recti distance in postnatal women. Validity, and relative and absolute reliability were found to be the strongest using the callipers.

Для цитирования: Benjamin Deenika R, Frawley Helena C, Shields Nora, Georgiou Chris, Taylor Nicholas F. Establishing measurement properties in the assessment of inter-recti distance of the abdominal muscles in a postnatal women.. Musculoskeletal science & practice. 2020. DOI: 10.1016/j.msksp.2020.102202.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.