DOI 10.1097/md.0000000000038370

Медицинская библиотека · Medicine · 2024

Efficacy and safety of interspinous process device compared with alone decompression for lumbar spinal stenosis: A systematic review and meta-analysis.

Zhu Changjiu, Xiao Guiling

СтатьяСистематический обзорМетаанализСравнительное исследованиеПеревод в очереди

Аннотация

STUDY

DESIGN

Systematic review and meta-analysis.

BACKGROUND

Interspinous process devices (IPD) were used as a treatment in selected patients with lumbar spinal stenosis (LSS). However, the use of IPD was still debated that it had significantly higher reoperation rates compared to traditional decompression. Therefore, the purpose of the meta-analysis was to evaluate the effectiveness and safety of IPD treatment in comparison to traditional treatment.

METHODS

The databases were searched of PubMed, Embase and the Cochrane, Chinese National Knowledge Infrastructure, Chongqing VIP Database and Wan Fang Database up to January 2024. Relevant studies were identified by using specific eligibility criteria and data was extracted and analyzed based on primary and secondary endpoints.

RESULTS

A total of 13 studies were included (5 RCTs and 8 retrospective studies). There was no significant difference of Oswestey Disability Index (ODI) score in the last follow-up (MD = -3.81, 95% CI: -8.91-1.28, P = .14). There was significant difference of Visual Analog Scale (VAS) back pain scoring in the last follow-up (MD = -1.59, 95% CI: -3.09--0.09, P = .04), but there existed no significant difference of leg pain in the last follow-up (MD = -2.35, 95% CI: -6.15-1.45, P = .23). What's more, operation time, bleeding loss, total complications and reoperation rate had no significant difference. However, IPD had higher device problems (odds ratio [OR] = 9.00, 95% CI: 2.39-33.91, P = .001) and lesser dural tears (OR = 0.32, 95% CI: 0.15-0.67, P = .002) compared to traditional decompression.

CONCLUSION

Although IPD had lower back pain score and lower dural tears compared with traditional decompression, current evidence indicated no superiority for patient-reported outcomes for IPD compared with alone decompression treatment. However, these findings needed to be verified in further by multicenter, double-blind and large sample RCTs.

Для цитирования: Zhu Changjiu, Xiao Guiling. Efficacy and safety of interspinous process device compared with alone decompression for lumbar spinal stenosis: A systematic review and meta-analysis.. Medicine. 2024. DOI: 10.1097/md.0000000000038370.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.