OBJECTIVE

Spondylotic changes in the cervical spine cause degeneration, leading to cervical spinal canal stenosis. This stenotic change can affect cerebrospinal fluid (CSF) dynamics by compressing the dural sac and reducing space in the subarachnoid space. We examined CSF dynamics at the craniovertebral junction (CVJ) using time-spatial labeling inversion pulse magnetic resonance imaging (Time-SLIP MRI) in patients with cervical spinal canal stenosis.

METHODS

The maximum longitudinal movement of the CSF at the CVJ was measured as length of motion (LOM) in the Time-SLIP MRI of 56 patients. The sum of ventral and dorsal LOM was defined as the total LOM. Patients were classified into 3 groups depending on their spinal sagittal magnetic resonance imaging findings: control (n = 27, Kang classification grades 0 and 1), stenosis (n = 14, Kang classification grade 2), and severe stenosis (n = 15, Kang classification grade 3).

RESULTS

Time-SLIP MRI revealed pulsatile movement of the CSF at the CVJ. The mean total, ventral, and dorsal LOM was 14.2 ± 9, 8.1 ± 5.7, and 3.8 ± 2.9 mm, respectively. The ventral LOM was significantly larger than the dorsal LOM. The total LOM was significantly smaller in the severe stenosis group (6.1 ± 3.4 mm) than in the control (16.0 ± 8.4 mm) or stenosis (11 ± 5.4 mm) groups (P < 0.001, Kruskal-Wallis H-test). In 5 patients, postoperative total LOM was improved after adequate decompression surgery.

CONCLUSIONS

This study demonstrates that CSF dynamics at the CVJ are influenced by cervical spinal canal stenosis. Time-SLIP MRI is useful for evaluating CSF dynamics at the CVJ in patients with spinal canal stenosis.

Для цитирования: Yamahata Hitoshi, Ijiri Kosei, Tanabe Fumito, Murasumi Kyoichi, Nagano Yushi, Makino Ryutaro, Higa Nayuta, Hanaya Ryosuke. Radiological Analysis of Cerebrospinal Fluid Dynamics at the Craniovertebral Junction Using Time-Spatial Labeling Inversion Pulse Magnetic Resonance Imaging in Patients with Cervical Spinal Canal Stenosis.. World neurosurgery. 2024. DOI: 10.1016/j.wneu.2024.02.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.