Optimizing the MRI protocol of the sacroiliac joints in Spondyloarthritis: which para-axial sequence should be used?

Giraudo Chiara, Magnaldi Silvia, Weber Michael, Puchner Antonia, Platzgummer Hannes, Kainberger Franz, Schueller-Weidekamm Claudia

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

To assess the diagnostic value of para-axial T2w-TSE (paT2) and fat-suppressed proton density (paPD-FS) MRI sequences for the evaluation of the sacroiliac joint (SIJ) of patients with axial Spondylarthritis (SpA).

MATERIALS AND

METHODS

One hundred and six patients with clinical findings suggestive of SpA underwent an MR protocol of the SIJ with additional paPD-FS (41 patients) and paT2 (105 patients). Acute (bone marrow oedema [BME], enthesitis, capsulitis, synovitis) and chronic findings (erosions, ankylosis) were assessed by paPD-FS and compared with the gold standard post-contrast sequences, whereas chronic features (because of the lack of fat suppression) were evaluated on paT2 and compared with pcT1.

RESULTS

paPD-FS demonstrated high sensitivity (98.9 %) and specificity (99.1 %) for BME; sensitivity and specificity for synovitis and enthesitis were 100 %; 85.7 % and 100 %, respectively, for capsulitis. paPD-FS and paT2 showed 100 % sensitivity and specificity for ankylosis; for erosions, paT2 demonstrated 85.3 % sensitivity and 100 % specificity, whereas paPD-FS, respectively, 98 % and 100 %.

DISCUSSION: PaT2 and paPD-FS provided precious information enabling an accurate interpretation of the heterogeneous findings of SpA. paPD-FS showed good results in detecting acute and chronic lesions and its inclusion in a routine MR examination of the SIJ could increase the diagnostic performance of a pre-contrast protocol.

KEY POINTS: Para-axial sequence should be included in a routine MRI protocol for SpA. Acute and chronic findings can be evaluated on para-axial PD-FS. Para-axial PD-FS is superior to para-axial T2-W in SpA.

Для цитирования: Giraudo Chiara, Magnaldi Silvia, Weber Michael, Puchner Antonia, Platzgummer Hannes, Kainberger Franz, Schueller-Weidekamm Claudia. Optimizing the MRI protocol of the sacroiliac joints in Spondyloarthritis: which para-axial sequence should be used?. European radiology. 2015. DOI: 10.1007/s00330-015-3790-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.