Using the cervical range of motion (CROM) device to assess head repositioning accuracy in individuals with cervical radiculopathy in comparison to neck- healthy individuals.

Wibault Johanna, Vaillant Jacques, Vuillerme Nicolas, Dedering Åsa, Peolsson Anneli

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This study had two purposes: to compare head repositioning accuracy (HRA) using the cervical range of motion (CROM) device between individuals with cervical radiculopathy caused by disc disease (CDD; n = 71) and neck- healthy individuals (n = 173); and to evaluate the test-retest reliability of the CROM device in individuals with CDD, and criterion validity between the CROM device and a laser in neck-healthy individuals, with quantification of measurement errors. Parameters of reliability and validity were expressed with intra- class- correlation coefficients (ICCs), and measurement errors with standard error of measurement (SEM) and Bland Altman limits of agreement. HRA (Mdn, IQR) differed significantly between individuals with CDD and neck- healthy individuals after rotation right 2.7° (6.0), 1.7° (2.7); and rotation left 2.7° (3.3), 1.3° (2.7) (p < = 0.021); 31% of individuals with CDD were classified as having impairment in HRA. The test-retest reliability of the CROM device in individuals with CDD showed ICCs of 0.79- 0.85, and SEMs of 1.4°- 2°. The criterion validity between the CROM device and the laser in neck-healthy individuals showed ICCs of 0.43- 0.91 and SEMs of 0.8°- 1.3°. The results support the use of the CROM device for quantifying HRA impairment in individuals with CDD in clinical practice; however, criterion validity between the CROM device and a laser in neck-healthy individuals was questionable. HRA impairment in individuals with CDD may be important to consider during rehabilitation and evaluated with the criterion established with the CROM device in neck-healthy individuals.

Для цитирования: Wibault Johanna, Vaillant Jacques, Vuillerme Nicolas, Dedering Åsa, Peolsson Anneli. Using the cervical range of motion (CROM) device to assess head repositioning accuracy in individuals with cervical radiculopathy in comparison to neck- healthy individuals.. Manual therapy. 2013. DOI: 10.1016/j.math.2013.02.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.