MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-025-09568-4

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025

Feasibility of synthetic CT images for robotic pedicle screw planning and navigation.

Kashtiara Ardavan, Beldé Sarah, Thijs Dieter, De Bondt Timo, Van Goethem Johan, Van de Kelft Erik

СтатьяПеревод в очереди

Аннотация

PURPOSE: Spinal robotic guidance platforms, which rely on computed tomography (CT) or cone beam CT (CBCT)-based navigation, enable precise preoperative planning and intraoperative placement of pedicle screws. However, they also result in significant radiation exposure to both patients and clinical staff. A recently FDA- and CE-approved high-resolution synthetic computed tomography (sCT) technology allows the generation of CT-equivalent images from magnetic resonance imaging (MRI) data, potentially reducing radiation exposure.

AIM: To assess the feasibility of using MRI-derived sCT images for pedicle screw planning and robotic navigation, and to compare patient radiation doses between standard CT-based and sCT-based workflows.

METHODS

Twelve patients scheduled for thoracolumbar pedicle screw fixation underwent 3T MRI with additional T1-weighted 3D dual-echo gradient-echo (GRE) sequences. These GRE datasets were converted into sCT images using BoneMRI® v1.8 (MRIguidance B.V.) and imported into the MAZOR™ robotic guidance system for preoperative planning, sCT-to-fluoroscopy fusion, and intraoperative navigation. Radiation doses were estimated using Monte Carlo-based NCICT and NCIRF dosimetry models, and compared to those from conventional CT-based workflows.

RESULTS

sCT images were visually comparable to conventional CT and fully compatible with the robotic navigation platform for both planning and execution. Replacing CT with sCT reduced patient radiation exposure by 98%, with residual dose primarily resulting from intraoperative fluoroscopy used for image fusion and verification.

CONCLUSION

MRI-derived sCT offers a radiation-free alternative to conventional CT for spinal robotic guidance, enabling pedicle screw planning and navigation while eliminating CT-associated radiation exposure.

Для цитирования: Kashtiara Ardavan, Beldé Sarah, Thijs Dieter, De Bondt Timo, Van Goethem Johan, Van de Kelft Erik. Feasibility of synthetic CT images for robotic pedicle screw planning and navigation.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2025. DOI: 10.1007/s00586-025-09568-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.