Accuracy in Step Counting Is Not Accuracy in Quantifying Walking Activity: A Criterion Validity Study of Wearable Devices Under Free-Living Conditions.

Chanteau Adrien, Faity Germain, Mahe Guillaume, Le Faucheur Alexis

СтатьяПеревод в очереди

Аннотация

PURPOSE: To determine the criterion validity of research- and consumer-grade wearables (18 step-based methods) for quantifying step counts and step-derived walking metrics in free-living conditions.

METHODS

Sixty healthy adults (20-80 years, balanced by sex and decade) wore six monitors for seven days: StepWatch (ankle), activPAL (thigh), ActiGraph (hip and wrist), Fitbit Inspire 2 (hip), Fitbit Charge 5 (wrist), and Garmin Vívoactive 4S (wrist), while wearing a waist-mounted video camera at their discretion during free-living sessions. Step counts from all devices were used to derive metrics of bout duration, frequency, and intensity. Raw ActiGraph data were also processed using five wrist-based machine-learning models for step detection. Video-identified steps labeled by trained researchers served as the criterion. Equivalence testing was performed using a ±10% equivalence margin.

RESULTS

Fifty-six participants provided 150 hours of valid video and 10,194 walking bouts. Only StepWatch fell within the equivalence margin for step counts with a mean absolute percent error (MAPE) <10%, with seven additional methods at 10-20%. For total walking bout duration, only activPAL and ActiGraph wrist-StepCount met equivalence criteria; activPAL achieved MAPE <10% and five others at 10-20%. No method met equivalence for the number of walking bouts, with MAPE >20% and balanced accuracy in bout detection <50%. For time spent in moderate-to-vigorous physical activity, activPAL (18.6%) and StepWatch (16.2%) achieved MAPE <20%, but no methods met equivalence.

CONCLUSIONS

The level of step-count accuracy obtained from wearable devices did not translate into a comparable level of accuracy in quantifying real-world walking activity. Overall, activPAL, StepWatch, ActiGraph hip/1s and ActiGraph wrist-StepCount showed the most consistent performance. These findings can help researchers select step-based methods that more accurately capture real-world walking patterns.

Для цитирования: Chanteau Adrien, Faity Germain, Mahe Guillaume, Le Faucheur Alexis. Accuracy in Step Counting Is Not Accuracy in Quantifying Walking Activity: A Criterion Validity Study of Wearable Devices Under Free-Living Conditions.. Medicine and science in sports and exercise. 2026. DOI: 10.1249/mss.0000000000004111.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.