The positional magnetic resonance imaging changes in the lumbar spine following insertion of a novel interspinous process distraction device.

Siddiqui Manal, Nicol Malcolm, Karadimas Efthimios, Smith Frank, Wardlaw Douglas

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

DESIGN

Patients with symptomatic lumbar spinal stenosis underwent magnetic resonance imaging to study changes in the lumbar spine in various postures before and after implantation of the X STOP Interspinous Process Distraction Device (St. Francis Medical Technologies, Concord, CA).

OBJECTIVE

To visualize the effect of the device in vivo.

SUMMARY OF BACKGROUND DATA: Previous studies have shown vertebral canal and exit foraminal area to reduce from flexion to extension. Recently, reports on improved kinematics in vitro at the implantation level of the X STOP device have also been published.

METHODS

Using positional magnetic resonance imaging, patients were scanned before and 6 months after surgery. Images were taken with the patient in sitting flexed, extended, neutral, and standing positions. The total range of motion of the lumbar spine and individual segments were measured, along with changes in disc height, areas of the exit foramens, and dural sac.

RESULTS

In 12 patients with 17 distracted levels, the area of the dural sac at these levels increased from 77.8 to 93.4 mm after surgery in the standing position (P = 0.006), with increase in the exit foramens, but no change in lumbar posture.

CONCLUSIONS

This study shows that the X STOP device increases the cross-sectional area of the dural sac and exit foramens without causing changes in posture.

Для цитирования: Siddiqui Manal, Nicol Malcolm, Karadimas Efthimios, Smith Frank, Wardlaw Douglas. The positional magnetic resonance imaging changes in the lumbar spine following insertion of a novel interspinous process distraction device.. Spine. 2005. DOI: 10.1097/01.brs.0000187878.79676.26.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.