MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10047-020-01162-3

Медицинская библиотека · Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2020

Effect of a modular neck hip prosthesis on anteversion and hip rotation in total hip arthroplasty for developmental dysplasia of the hip.

Nakahara Ema, Uemura Keisuke, Ando Wataru, Hamada Hidetoshi, Takao Masaki, Sugano Nobuhiko

СтатьяПеревод в очереди

Аннотация

Total hip arthroplasty (THA) is often required to decrease the excessive anatomical femoral anteversion (AA) in developmental dysplasia of the hip. Studies have recommended decreasing the AA via the use of a retroverted modular neck. However, hip rotation after THA may strengthen or weaken the effect of changing the AA. Thus, the present study analyzed the effect of a retroverted neck on AA and hip rotation. Patients who underwent THA using a straight neck (ST group) or a 15° retroverted neck (RV group) in a version changeable dual modular system (Mainstay stem, Kyocera, Kyoto, Japan) were retrospectively reviewed. After matching for age, body mass index, and surgical approach, 44 patients were included in each group. The AA and hip rotation (femoral rotational angle: FRA) were measured on CT images acquired preoperatively and 1 month after THA, and were compared between the groups. The mean ± standard deviation preoperative AA of the ST group (26.1 ± 10.7°) was significantly smaller than that of the RV group (44.2 ± 7.8°) (p < 0.001). In contrast, the postoperative AA did not significantly differ between the groups (ST group 27.5 ± 9.8°, RV group 25.1 ± 8.3°, p = 0.406). The change in FRA after THA did not significantly differ between the groups (ST group - 3.8 ± 9.9°, RV group - 3.5 ± 9.1°, p = 0.841). In conclusion, a 15° retroverted neck was useful in controlling AA in hips with excessive AA, and the change in FRA after THA did not differ between the ST group and the RV group.

Для цитирования: Nakahara Ema, Uemura Keisuke, Ando Wataru, Hamada Hidetoshi, Takao Masaki, Sugano Nobuhiko. Effect of a modular neck hip prosthesis on anteversion and hip rotation in total hip arthroplasty for developmental dysplasia of the hip.. Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs. 2020. DOI: 10.1007/s10047-020-01162-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.