MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4055/cios.2015.7.3.351

Медицинская библиотека · Clinics in orthopedic surgery · 2015

Evaluation of the Effusion within Biceps Long Head Tendon Sheath Using Ultrasonography.

Park In, Lee Hyo-Jin, Kim Sung-Eun, Bae Sung-Ho, Lee Kwang-Yeol, Park Kwang-Sun, Kim Yang-Soo

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Many shoulder diseases are related to glenohumeral joint synovitis and effusion. The purpose of the present study is to detect effusion within the biceps long head tendon sheath as the sign of glenohumeral joint synovitis using ultrasonography, and to evaluate the clinical meaning of effusion within the biceps long head tendon sheath.

METHODS

A consecutive series of 569 patients who underwent ultrasonography for shoulder pain were reviewed retrospectively and ultimately, 303 patients were included. The authors evaluated the incidence and amount of the effusion within the biceps long head tendon sheath on the ultrasonographic short axis view. Furthermore, the authors evaluated the correlation between the amount of effusion within the biceps long head tendon sheath and the range of motion and the functional score.

RESULTS

The effusion within the biceps long head tendon sheath was detected in 58.42% of the patients studied: 69.23% in adhesive capsulitis, 56.69% in rotator cuff tear, 41.03% in calcific tendinitis, and 33.33% in biceps tendinitis. The average amount of the effusion within the biceps long head tendon sheath was 1.7 ± 1.6 mm, and it was measured to be the largest in adhesive capsulitis. The amount of effusion within biceps long head tendon sheath showed a moderate to high degree of correlation with the range of motion, and a low degree of correlation with the functional score and visual analogue scale for pain in each type of shoulder disease.

CONCLUSIONS

The effusion within the biceps long head tendon sheath is closely related to the range of motion and clinical scores in patients with painful shoulders. Ultrasonographic detection of the effusion within the biceps long head tendon sheath might be a simple and easy method to evaluate shoulder function.

Для цитирования: Park In, Lee Hyo-Jin, Kim Sung-Eun, Bae Sung-Ho, Lee Kwang-Yeol, Park Kwang-Sun, Kim Yang-Soo. Evaluation of the Effusion within Biceps Long Head Tendon Sheath Using Ultrasonography.. Clinics in orthopedic surgery. 2015. DOI: 10.4055/cios.2015.7.3.351.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.