OBJECTIVE

Case ascertainment through self-report is a convenient but often inaccurate method to collect information. The purposes of this study were to develop, assess the sensibility, and validate a tool to identify cases of systemic autoimmune rheumatic diseases (SARD) in the outpatient setting.

METHODS

The SARD tool was administered to subjects sampled from specialty clinics. Determinants of sensibility - comprehensibility, feasibility, validity, and acceptability - were evaluated using a numeric rating scale from 1-7. Comprehensibility was evaluated using the Flesch Reading Ease and the Flesch-Kincaid Grade Level. Self-reported diagnoses were validated against medical records using Cohen's κ statistic.

RESULTS

There were 141 participants [systemic lupus erythematosus (SLE), systemic sclerosis (SSc), rheumatoid arthritis, Sjögren syndrome (SS), inflammatory myositis (polymyositis/dermatomyositis; PM/DM), and controls] who completed the questionnaire. The Flesch Reading Ease score was 77.1 and the Flesch-Kincaid Grade Level was 4.4. Respondents endorsed (mean ± SD) comprehensibility (6.12 ± 0.92), feasibility (5.94 ± 0.81), validity (5.35 ± 1.10), and acceptability (3.10 ± 2.03). The SARD tool had a sensitivity of 0.91 (95% CI 0.88-0.94) and a specificity of 0.99 (95% CI 0.96-1.00). The agreement between the SARD tool and medical record was κ = 0.82 (95% CI 0.77-0.88). Subgroup analysis by SARD found κ coefficients for SLE to be κ = 0.88 (95% CI 0.79-0.97), SSc κ = 1.0 (95% CI 1.0-1.0), PM/DM κ = 0.72 (95% CI 0.49-0.95), and SS κ = 0.85 (95% CI 0.71-0.99). The screening questions had sensitivity ranging from 0.96 to 1.0 and specificity ranging from 0.88 to 1.0.

CONCLUSION

This SARD case ascertainment tool has demonstrable sensibility and validity. The use of both screening and confirmatory questions confers added accuracy.

Для цитирования: Armstrong Susan M, Wither Joan E, Borowoy Alan M, Landolt-Marticorena Carolina, Davis Aileen M, Johnson Sindhu R. Development, Sensibility, and Validity of a Systemic Autoimmune Rheumatic Disease Case Ascertainment Tool.. The Journal of rheumatology. 2016. DOI: 10.3899/jrheum.160327.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.