MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/thc-161277

Медицинская библиотека · Technology and health care : official journal of the European Society for Engineering and Medicine · 2017

Fracture risk of vertebral bodies after cryosurgery using a miniature cryoprobe: A biomechanical in-vitro analysis on human bones.

Zarghooni K, Westermann L, Sobottke R, Röllinghoff M, Bredow J, Siewe J, Eysel P, Scheyerer M J

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Due to spinal instability and compressive neurologic deficits surgical management is sometimes necessary in patients with metastatic spinal lesions. However, in some cases open surgery is not possible and minimally invasive procedures, like cryoablation, are needed. The aim of the current study was to investigate whether a miniature cryoprobe provides adequate tissue cooling in vertebrae and to evaluate the direct impact of cryosurgery on vertebral body stability.

MATERIALS AND

METHODS

Twelve thoracic vertebral bodies were harvested from fresh cadavers. After documenting bone density cryoablation was performed in six vertebral bodies according to a standardized procedure. Afterwards temperature inside the vertebral body and maximum breaking force were measured in the control and experimental groups.

RESULTS

Required temperature of -50° was reached in all areas. There was a significant correlation between maximum breaking force and measured bone density (p= 0.001). Mean breaking force within the experimental group was 5047 N (SD = 2955 N) compared to 4458 N (SD = 2554 N) in the control group. There were no observable differences in maximum breaking force between both groups.

CONCLUSION

Miniature cryoprobe can deliver adequate tissue cooling to -50°C in vertebral bodies. The procedure does not seem to influence breaking force of the treated bones in-vitro. Therefore, using miniature probes cryosurgery may provide a valuable alternative to conventional surgical resection of neoplastic diseases as well as of benign locally aggressive bone tumors.

Для цитирования: Zarghooni K, Westermann L, Sobottke R, Röllinghoff M, Bredow J, Siewe J, Eysel P, Scheyerer M J. Fracture risk of vertebral bodies after cryosurgery using a miniature cryoprobe: A biomechanical in-vitro analysis on human bones.. Technology and health care : official journal of the European Society for Engineering and Medicine. 2017. DOI: 10.3233/thc-161277.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.